True RMS clamp meter: This voltmeter can accurately measure AC current, AC / DC voltage, frequency or duty cycle, resistance, capacitance, as well as diode, continuity and temperature tests. True RMS for accurate measurement of nonlinear loads. Easy to use in laboratory, factory and home.
Low Z and LPF: low input impedance helps prevent false readings due to ghost voltage. Low pass (LPF) and frequency conversion filters are used for accurate measurement of motor drive signals. To measure the current, you need to clamp the meter to one wire, not the entire power line.
NCV fault function: non contact voltage detection, through measuring the EM field strength, effectively check the current state, without touching any wires; The NCV button is on the right. Just push your thumb on it.
| Specifications | Range | Accuracy |
| HT206B | ||
| DC Voltage | 600V | / |
| 600mV/6V/60V/600V/600V | ±(0.5%+3) | |
| AC Voltage | 600V | / |
| 6V/60V/600V/600V | ±(1.0%+3) | |
| AC Current | 2A/20A/200A | ±(2.5%+5) |
| Resistance | 2KΩ/20KΩ | / |
| 600Ω/6KΩ/60KΩ/600KΩ/6MΩ/60MΩ | ±(1.0%+3) | |
| Capacitance | 10nF/100nF/1uF/10uF/100uF/1mF/10mF | ±(4.0%+3) |
| Frequency | 10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz | ±(0.5%+5) |
| Duty | 1%~99% | ±(1.0%+2) |
| Temperature(℃/°F) | -40℃~1000℃ | ±(1.0%+2) |
| -40°F~1832°F | ±(1.0%+2) | |
| Counters | 6000 counters | |
| Auto/manual range | Auto | |
| Continuity(sound and light alarm) | √ | |
| Diode test | √ | |
| Data hold | √ | |
| NCV(sound and light alarm) | √ | |
| Backlight | √ | |
| Flashlight | √ | |
| Low battery indication | √ | |
| Auto power off | √ | |
| True RMS | √ | |
| LPF | √ | |
| Max/MIN | √ | |
| LowZ | √ | |
| Power | 2*AAA(1.5V)batteries | |
| Weight | Appro*.260g | |
| Size | 193mm*73mm*34mm | |
| Safety rating | EN61010-1,-2-030 EN61010-2-033,EN61326-1 CAT III 600V | |