+86-312-6775656
HZBS-002 Abel Close Cup Flash Point Test Equipment

HZBS-002 Abel Close Cup Flash Point Test Equipment

HZBS-002 Abel Closed Cup Flash Point Tester Characteristics HZBS-002 is designed according to ISO13736 and IP 170 by Abel close cup method, it is suitable to the determination of flash point of petroleum product and other flammable liquid with flash point between -30℃ and 70℃. The precision for this method is only valid for flash points...
Product Details ofHZBS-002 Abel Close Cup Flash Point Test Equipment

Huazheng Electric Manufacturing (Baoding) Co., Ltd. is one of the leading manufacturers and suppliers of hzbs-002 abel close cup flash point test equipment in China. Please feel free to buy high quality equipment for sale here from our factory. Good service and reasonable price are available.

 

HZBS-002 Abel Close Cup Flash Point Test Equipment

Characteristics

HZBS-002 is designed according to ISO13736 and IP 170 by Abel close cup method, it is suitable to the determination of flash point of petroleum product and other flammable liquid with flash point between -30℃ and 70℃. The precision for this method is only valid for flash points in range of --5℃ and 66.5℃. It is not applicable to water-borne paints.


Main characteristics:

◆ Temperature rise controlled by SSR, which can satisfy requirements of different heating rate.

◆ Continuously stirring the sample and stirring is auto stopped during igniting.

◆ Electrical controlled ignition.

◆Test cup lid with stirring device can be disassembled freely..


Main parameters

Test temperature range: -30℃ ~18.5℃ if equipped with cooling bath(-30℃ ~18.5℃ if equipped with cooling bath

19℃ ~70℃ if normal working temperature

Heating power: 0 ~450W adjustable

Temperature rise rate: 1℃/min

Flame can be adjusted to 3~4mm

String rate: 0-40 roll/min adjustable


Operation

Preparation

After successful commissioning, instrument can start normal operation. For testing operation procedures, see ASTM test method standard.

Heating rate

Load sample as requirement, turn on "POWER" and "RUN": button, adjust voltage dial to heat the sample, observe thermometer reader, and adjust the voltage suitably so as to meet the test requirement.

Temperature rising rate: 1℃/min

Test condition

Get through the gas source and ignite the ever-light flame and pilot flame, adjust the size of pilot flame to 3mm-4mm, and adjust ever-light flame to a little bigger. Press "FIRE" for 1 second, the pilot flame will be descended.

When test operation is complete, adjust voltmeter back to "0", turn off "RUN", switch off gas source, remove all liquid medium in the bath.

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

image014

image016

Request for quote_

Hot Tags: HZBS-002 Abel Close Cup Flash Point Test Equipment, China, suppliers, manufacturers, price, for sale, Abel Closed Cup Flash Point Tester, abel semiautomatic flash point tester, abel semi automatic flash point test instrument Manual, manual flash point tester, open cup flash point test machine, Transformer Oil Flash Point Tester, ip 170 flash point tester, flash point test equipment, flash point measuring device

Send Inquiry

(0/10)

clearall