HZJQ-1 Transformer Oil BDV Test Kit 80kV 100kV 1. Simple operation. The machine will automatically complete the withstand voltage test on one cup of sample oil after simple setting by the operator. Breakdown voltage value of 1 to 6 times and recurrent times will be automatically saved. After the...
Product Details ofHZJQ-1 Transformer Oil BDV Test Kit 80kV 100kV

 

HZJQ-1 Transformer Oil BDV Test Kit 80kV 100kV

HZJQ-1 Transformer Oil BDV Test Kit

HZJQ-1 Oil BDV Test Equipment

Summary

HZJQ-1 Transformer Oil BDV Test Kit is a scientific and technical product of our company. According to the relevant provisions of national standard GB507-1986 and industrial standard DL/T846.7-2004 As well as ASTM D1816 and ASTM D877. Transformer Oil BDV Test Kit has been carefully researching and developing high-precision and all-digital industrial equipment through a large number of field tests and long-term unremitting efforts by exerting its advantages.In order to meet the needs of different users, this series of instruments can be divided into single cup, three cup, cup type, etc.The instrument is simple in structure and elegant in shape.Due to the use of automatic digital computer control, so high measuring accuracy, strong anti-interference ability, safe and reliable.

image001

Major Factor

ParameterSpecification
Output Voltage0~80 kV (100 kV optional)
Voltage Distortion Rate<3%
Voltage Raising Speed0.5~5 kV/s (adjustable)
Standing Time15 min (adjustable)
Boosting Interval5 min (adjustable)
Boosting Frequency1~9 times (optional)
Booster Capacity1.5 kVA
Measuring Accuracy±3%


Precautions

1. The selection, placing and electrode distance of the oil sample before testing shall meet relevant national and industrial standards.

2. The operators or other personnel are strictly forbidden to touch the casing after the power is switched on to avoid accidents.

3. The power shall be cut off immediately if any abnormal event is found during the operation.


Maintenance

1. This equipment shall not be exposed in moist environment.

2. Keep the oil cup and the electrodes clean. Fill the cup with fresh transformer oil for protection during its idle. Check the electrode distance and check the tightness between the electrode tip and electrode bar screw thread before the cup is used again.


Packing List

No.

Item

Qty

1

Main engine

1

2

Oil Cup

1

3

Elbow

2

4

Stirrer

2

5

Tweezers

1

6

Feeler gauge

1

7

Power line

1

8

Fuse pipe

2

9

Print paper

2

10

Allen wrench

1

HZJQ-1_04

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

Customer Visit

Case

Request for quote_

Hot Tags: HZJQ-1 Transformer Oil BDV Test Kit 80kV 100kV, China, suppliers, manufacturers, price, for sale, Insulating oil bdv tester, 100 kv oil vbd test, dielectric oil tester 60 kv, transformer oil bdv test device, bdv test kit 60kv, iec 60156, BDV Measuring Kit, 60kv 80kv portable transformer oil bdv tester hzjq-1, oil insulation test kit, OIL CAP FOR 100KV TRANSFORMER OIL BDV TESTER, 80 kv auto portable oil test, 90kV Liquid Dielectric Breakdown Tester, oil insulation test kit 100kv, huazheng bdv 80kv, insulating oil test kit 100kv bdv, fully automatic transformer oil testing kit tool, portable bdv measuring kit, bdv test kit specification, dielectric strength bdv testing kit, bdv measuring kit, insulating oil dielectric strength tester, Transformer Oil Breakdown Voltage Test Set, breakdown voltage meter, transformer oil bdv test equipment, Transformer Oil BDV Tester

Send Inquiry

(0/10)

clearall