+86-312-6775656
HZZL-3 ASTM D971 Transformer Oil Interfacial Tension Meter
video
HZZL-3 ASTM D971 Transformer Oil Interfacial Tension Meter

HZZL-3 ASTM D971 Transformer Oil Interfacial Tension Meter

The HZZL-3 ASTM D971 Transformer Oil Interfacial Tension Meter is a simple and easy to use testing instrument that uses physical methods instead of chemical methods.
Product Details ofHZZL-3 ASTM D971 Transformer Oil Interfacial Tension Meter

 

HZZL-3 ASTM D971 Transformer Oil Interfacial Tension Meter

Product Introduction

The ASTM D971 Transformer Oil Interfacial Tension Meter is a simple and easy to use testing instrument that uses physical methods instead of chemical methods. The amount of intermolecular tension reflects the physicochemical properties of the liquid sample and is one of the important indicators of product quality. And our ASTM D971 Transformer Oil Interfacial Tension Meter with automatic interfacial tension meter can quickly and accurately measure the surface and interfacial tension values of various liquids, and display the results automatically.

Features

Our ASTM D971 Transformer Oil Interfacial Tension Meter has won the favor of users in the market with its good performance and reasonable price. It adopts electromagnetic force balance type sensor to improve the measurement accuracy, and it is very convenient to adjust the instrument by calibrating one point. It is integrated temperature detection circuit, which automatically compensates the temperature for the test results. The instrument has RS232 interface device, which can be connected with computer to facilitate data processing.

CE of HZZL-3 ASTM D971 Interfacial Tension Meter For Transformer Oil

Transformer Oil Interfacial Tension Meter

Transformer Oil Interfacial Tension Meter

Transformer Oil Interfacial Tension Meter

Transformer Oil Interfacial Tension Meter

Transformer Oil Interfacial Tension Tester

HZZL-3 Surface tension tester

Technical Characteristics

Measuring Range

0-200mN/m

Accuracy

0.1%( test result)±0.1 mN/m

Precision

0.1mN/m

Sensibility

0.1mN/m

Mains Voltage

AC220V±20%, 50HZ±10%

Maximum Power Dissipation

20W

Suit Ambient Temperature

10~30℃(25℃the best)

Matters needing attention

1. Working environment:

The working environment of the instrument should meet the requirements mentioned in Chapter 4.

2. Platinum ring:

The plane of the ring should be parallel to the page on the north side, and the ring must maintain a certain degree of roundness. The platinum ring should be clean. It can be cleaned with detergent, then rinsed thoroughly with pure water. After cleaning, heat the platinum wire in the oxidizing flame of an alcohol lamp until it glows orange-red.

3. Test cup:

The test cup should be clean, and it can be cleaned and washed, then rinsed with hot water, and finally rinsed with pure water, and drained before use.

4. Obtaining pure water:

It is best to use distilled water that has been purified multiple times. Tests have shown that some commercially available purified drinking water can meet the experimental requirements.

5. Calibration of the instrument:

After the instrument is subjected to a large impact, or after moving, the weight in the setting items should be calibrated.

huazheng company info

image014

image016

Request for quote_

Hot Tags: HZZL-3 ASTM D971 Transformer Oil Interfacial Tension Meter, China, suppliers, manufacturers, price, for sale, transformer oil interfacial tension test, automatic dunouy interfacial tensiometer for Liquid Petroleum, Interfacial Tension Tester, surface tension measurement equipment, force tensiometer, hzzl-3, hzzl3, ASTM D 971, Interface Tension Meter, Inter facial Tension Oil Tester, ASTMD971 automatic interface tension meter, freezing point apparatus, Water Separability Test Apparatus, pour point analyzer, astm d1500 colorimeter, calorific value testing lab, calorific value measuring device