1. The effect of polarity of test voltage on current leakage

Transformers are prone to moisture, usually caused by their outer skin. Normally, the electrical properties of water molecules in an electric field are positive, but if a positive voltage is applied to the winding of a transformer, it will cause changes in the water molecules, resulting in a continuous decrease in water volume and a decrease in the amount of current passing through the transformer. When the applied voltage is negative, the amount of current passing through the transformer will increase. However, in reality, not all transformers are affected by voltage polarity. For example, new power transformers generally do not experience moisture, so the water content in new transformers is extremely low and can even be ignored. It seems that there is no certain connection between the polarity of the test voltage and current leakage.

2. The influence of temperature on high-pressure testing

The change in temperature will fully affect the insulation resistance. Therefore, as the external temperature continues to rise, the movement of molecules and ions in the insulation material will also accelerate with the increase in temperature, leading to an increase in the polarity of the insulation resistance and a decrease in the insulation resistance. At the same time, as the temperature continues to rise, the movement speed of water molecules in the insulation resistance will also continue to accelerate, allowing impurities on the surface of the insulation resistance to dissolve quickly, resulting in a rapid decrease in resistance. In addition, the decrease in insulation resistance is directly related to surface dirt. At the same time, analysis of some research data shows that changes in temperature can also cause certain changes in the insulation absorption ratio of transformers. In this case, it can be divided into two situations. For dry variable pressure aluminum, the absorption ratio will increase with an increase in temperature. However, once the temperature rises above 40 degrees Celsius, a decrease will occur. In other cases, an increase in temperature will result in a decrease in absorption ratio.

3. Impact of Boost Speed

During the high-voltage test, the speed of boosting will affect the leakage of current. Therefore, in the test, it is necessary to flexibly grasp the capacity of the transformer and control the occurrence of errors as much as possible to ensure the accuracy of the high-voltage test results.

Send Inquiry