HZ-2009 High Voltage Switch Circuit Breaker Analyzer
video
HZ-2009 High Voltage Switch Circuit Breaker Analyzer

HZ-2009 High Voltage Switch Circuit Breaker Analyzer

HZ-2009 High Voltage Switch Circuit Breaker Analyzer Please notice that it's only allowed to work with well trained personnel and with the power systems familiar personnel.
[[ProductRating]]
Product Details ofHZ-2009 High Voltage Switch Circuit Breaker Analyzer

 

HZ-2009 High Voltage Switch Timing Test Circuit Breaker Analyzer

High-voltage circuit breaker analyzer is suitable for mechanical characteristic testing of SF6 switches, GIS composite electrical appliances, vacuum switches, and oil switches.

Capable of performing five test modes - including time test, time-motion test, minimum trip voltage test, and life-cycle endurance test - across five operation sequences (O, C, O-C, C-O, O-C-O, C-O-C), the HZ-2009 captures every parameter defined by IEC 62271 and IEEE C37 standards: closing time, opening time, bounce time, contact travel, over-travel, overshoot, rebound, and instantaneous/average velocity. Results are displayed as both a numerical table and a waveform graph on the 5.7-inch transflective LCD, with instant printing on the built-in 58mm thermal printer and export via USB flash drive or PC software to Word/Excel.

circuit breaker analyzer

Application Industries

Industry Typical Use Case
Power Utilities & Substations Commissioning, routine maintenance, and diagnostic testing of HV/MV circuit breakers in transmission and distribution substations
Switchgear Manufacturers Factory acceptance testing of vacuum, SF6, and air-blast circuit breakers
Industrial Facilities Verification of motor protection breakers, bus section breakers, and tie breakers in industrial power systems
Railway Electrification Testing traction substation circuit breakers and section switches
GIS & AIS Substations Testing gas-insulated switchgear interrupters and disconnecting circuit breakers
Electrical Testing Services Third-party circuit breaker commissioning, diagnostic audits, and post-maintenance verification
Utilities Asset Management Life-cycle condition assessment and trending over multiple maintenance intervals

 

High Voltage Circuit Breaker Analyzer Precautions

1. Please notice that it's only allowed to work with well trained personnel and with the power systems familiar personnel.

2. The connect action of the test lines should be done before supply power to the instrument.

3. When the instrument is turned on, do not touch the measurement circuit, control output circuit and the conductors connected to it. Before connecting the input or output terminals of the instrument, be sure to ground the instrument reliably.

4. Try to use the special test leads and accessories provided by this instrument.

5. In the case of connecting the DC output line, before turning on the power switch and control switch of the instrument, be sure to confirm that the switch is malfunctioning, so as not to cause any possible personal and equipment hazards.

6. Avoid using it in humid, flammable and explosive environments.

7. The power supply of the instrument is 220V AC, and 380V is prohibited.

HZ-2009 High Voltage Circuit Breaker Analyzer

High Voltage Circuit Breaker Analyzer

High Voltage Circuit Breaker Analyzer

High Voltage Circuit Breaker Analyzer

circuit breaker tester (3)

High Voltage Circuit Breaker Analyzer Technical Characteristics

Test channels

12 channels with 25V, the current is 50mA

Transducer

One analog transducer.

TIME

Recording time length

0~20.0s

Time accuracy

±0.l%reading ± 2 LSB

Resolution

0.1ms

Motion

Range

0~1000mm

Accuracy

±1% reading ±1LSB

Resolution

0.1mm

Velocity

Ranges

0.01~20.00m/s

Accuracy

±1%reading ±1LSB

Resolution

0.01m/s

DC POWER

Ranges

5~260V

Max current

20A

Accuracy

±1%reading ±1LSB

Load change

≤1%

TRIGGER

Voltage

5~260V

Current

0.1-20A

Transducer

The transducer states changes

Channels

Channels states changed

DIMENSIONS

415mm×320mm×168mm

WEIGHT

8kg

OPERATION TEMPERATURE

-10℃~50℃

HUMIDITY

≤80% RH

POWER SUPPLY

Voltage

AC 220V±10%

FREQUENCY

50Hz±10%

SAFETY

Insulation resistance

>2MΩ

Leakage current

<3.5mA

Immunity

AC 1500V 50Hz, 1min.

 

FAQ

Q1: What parameters does it measure? Time, sync, bounce, stroke, velocity, trip Volt.

Q2: Which breaker types can it test? VCB, SF6, oil, GIS. MV 3.3kV to EHV 500kV.

Q3: How does the automatic minimum trip voltage test work? Auto steps voltage, stops at first success.

Q4: How do I install the travel sensor? Linear: clip+M5. Rotary: align axis, 120/345°.

Q5: How do I export results and create reports? USB or PC software. Export Word/Excel report.

Huazheng Factory Show

Huazheng Certificate

Huazheng Exhibition

Request for quote_

Hot Tags: HZ-2009 High Voltage Switch Circuit Breaker Analyzer, China, suppliers, manufacturers, price, for sale, circuit breaker analyzer testing equipment, circuit breaker analyzer tester, circuit breaker analyzer hs code 90309090, High Voltage Switching Test System, hz-2009, hz2009, Circuit breaker vibration analyzer, circuit breaker analayser, high voltage circuit breaker analysis system, CB dynamic mechanical analyzer, circuit breaker test equipment, High Voltage Switch Circuit Breaker Analyzer, circuit breaker test unit, circuit breaker test set, Ampere Second Characteristic Tester, DC Circuit Breaker Test Set