HZHG Series 150kV AC/DC Voltage Voltmeter Divider Overview This series of AC and DC high voltage divider is dedicated precision instrumentation for on-site field measurements, both high voltage DC measurements, and can measure AC high voltage. The equipment consists of pressure device and measuring instrument is...
Send Inquiry
Product Details ofHZHG Series 150kV AC/DC Voltage Voltmeter Divider

Huazheng Electric Manufacturing (Baoding) Co., Ltd. is one of the leading manufacturers and suppliers of hzhg series 150kv ac/dc voltage voltmeter divider in China. Please feel free to buy high quality equipment for sale here from our factory. Good service and reasonable price are available.

 

HZHG Series 150kV AC/DC Voltage Voltmeter Divider

 

Overview

This series of high voltage dividers is dedicated precision instrumentation for on-site field measurements, capable of measuring both DC high voltage and AC high voltage. The measuring system comprises a high-voltage divider cylinder and a dedicated digital peak voltmeter

 

Indicators

Voltage grade

AC/DC150kV

Pressure ratio

1000:1 (Calibrated Divider Ratio)

Impedance

600MΩ

Accuracy

DC Voltage Class 1.0 (±1.0%)
AC Voltage (RMS) Class 1.5 (±1.5%)

 

Use Of Instruction

Assembly

Begin by opening the upper cover of the aluminum alloy case. Hold the voltage-sharing ball and rotate it counterclockwise to unscrew and remove it. Remove the divider cylinder, the special digital measuring instrument, and the special cable from the case. Screw the ball back onto the divider cylinder and place the assembly in the required position.

Grounding

On the base of the divider, securely connect the ground wire to earth ground. Proper grounding is essential for safe operation.

High-Voltage Connection

Firmly connect the high-voltage test lead to the ball at the top of the divider, ensuring a secure and reliable connection.

Measuring Instrument Connection

Insert the special cable end into the divider output port. Insert the other end into the voltage measurement input port of the measuring instrument. Ensure that the connection is secure to guarantee accurate measurement.

Measurement Mode Selection

According to the measurement requirements, select the appropriate position on the measuring instrument. Set the bottom switch to the required AC or DC range.

Testing

Apply high voltage and record the data as required.

Shutdown and Dismantling

After a short period, when the instrument displays zero voltage, dismantle the test circuit safely.

 

Note

Clean Working Area: Keep the area around the equipment free of debris to avoid affecting measurement accuracy.

Safe Operating Distance: Maintain the required operating distance strictly to ensure operational safety.

Connection Check: Verify that all connections are secure, especially the grounding wire connection.

Post-Measurement Safety: After measurement, do not enter the test area until the meter reading returns to zero.

Overpressure Prohibition and Storage: Strictly avoid overpressure operation. Keep the equipment surface clean. When not in use, store it in a cool, dry place.

 

150kV AC/DC Voltage Voltmeter Divider

Customer Visit

Case

Request for quote_

Hot Tags: hzhg series 150kv ac/dc voltage voltmeter divider, China, suppliers, manufacturers, price, for sale, pd free hipot tester, non partial discharge testing transformer, pd free high voltage testing transformer, partial discharge free test system, ac withstand voltage testing set, non partial discharge testing system