Technical Parameters

1.the operating conditions of the system

product-130-251

Altitude: ≤ 2000 m

Ambient Temperature: –10 to +45 °C

Relative Humidity: <90% (–10 to 40 °C)

Max. Daily Temperature Difference: 30 °C

Atmospheric Pressure: 0.1 MPa

Atmospheric Humidity: 11 g/m³

Earthquake Intensity: ≤ Class 8

Environment: Indoor use

 

2.Capacitor divider (also as a coupling capacitor)

Parameter Details
Model HZTRF600-0.002
Rated Frequency 50Hz ~ 200Hz
Cooling Method ONAN (Oil Natural Air Natural)
Accuracy Class Class 2
Single Capacitor Capacity 4000 pF
Rated Capacity 2000 pF
Rated Voltage 600 kV
Nominal Voltage Division Ratio 2000:1
Dielectric Loss < 0.2%
Temperature Coefficient < 0.0004 (per °C, typical for capacitive components)
Over-Voltage Capability Withstand 110% rated voltage (660 kV) for 110 seconds without insulation damage
Measurement Accuracy ±1% Full Scale
Continuous Operation Long-term continuous running capability

 

Low-Voltage Arm Withstand Voltage: 3 kV / 1 min. The high-voltage and low-voltage arms are made of the same medium to ensure that the voltage division ratio of the device is not affected by temperature.

Structure: Insulated housing oil-immersed capacitor structure, consisting of a top cover, capacitor body, moving chassis, and low-voltage arm. The following components - excluding the movable base plate, pressure-proof cover, and other insulation accessories - must maintain a partial discharge level below 5 pC at rated voltage. The insulation withstand voltage requirement is less than 550 kV without abnormal discharge.

Top Pressure-Receiving Hood Structure: The pressure hood is made of high-quality LY2 pure aluminum plate. The welding process uses a submerged arc welding machine to ensure long-term oxidation resistance in air. The radius of curvature is designed such that no corona phenomenon occurs on the equalizing hood under 550 kV power frequency voltage.

Special attention: The above-mentioned parts must undergo hot-dip galvanizing after metal processing to prevent iron oxidation in air, which could otherwise lead to corona discharge after oxidation.

 

Digital peak voltmeter

Model: PV2-1

Function: The peak voltmeter is mainly used for voltage measurement of power frequency withstand voltage test. It can measure the power frequency test voltage and true RMS value, so it must have the following functions:

1) Input voltage range: The input voltage range is 700V, and the indicated voltage peak value /product-1-1 or the true RMS value;

Notes: it refers to the input range of the peak meter. AS per The nominal partial pressure ratio 2000:1 and rated voltage 600Kv, we can calculate that the input voltage value range=600KV/2000=300V. So our parameter 700V can totally meet your demands.

2) this voltage is the actual voltage input by the meter: input voltage = test voltage / partial pressure ratio;

3) Peak recurrence: peak/effective value display selection:

4)voltage display: The voltage display uses a 4-digit half-digit table. Directly display the true rms or peak value of the test voltage. The unit of reading is kilovolts;

5) the ratio setting switch: the switch is a four-digit number, indicating that the transformation ratio can be up to 9999. The test can change the partial pressure ratio of the actual test by the digital button, which can make the measurement data more accurate;

6) the accuracy level is not lower than the level 1 peak voltmeter has the function of measuring RMS, peak, peak / √ 2, and can record (maintain) the voltage value when flashover; system measurement error: in accordance with IEC60060-2;

7) Self-holding function of the discharge voltage value of the overvoltage value at the moment of discharge.

 

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

image012

image014

Request for quote_

Hot Tags: hztrf600-0.002 600kv high voltage divider with peak voltmeter, China, suppliers, manufacturers, price, for sale, telescopic discharge rod, acdc kilovoltmeters, AC Withstand Voltage Test Platform, variac transformer manual voltage regulator, estabilizador regulator variac, Contact Voltage Regulator