+86-312-6775656
HZ-9760A Portable Gas Chromatograph For Transformer Oil

HZ-9760A Portable Gas Chromatograph For Transformer Oil

HZ-9760A Portable Gas Chromatograph For Transformer Oil I.Technical parameters 1.Detection limit(Unit卩L/L): 2.Detector technical indicators: 3.Temperature control index: 4.Other parameters: Dimensions: 625 x500 x297mm Power supply: 220V±22V, 50Hz Weight: <15kg Power: ≤600W II.Technical characteristics 1. Highly integrated integrated design: The...
Product Details ofHZ-9760A Portable Gas Chromatograph For Transformer Oil

Portable Gas Chromatograph For Transformer Oil

I.Technical parameters

1.Detection limit(Unit卩L/L):

Component

Detection limit

Component

Detection limit

H2

2

ch4

0.05

CO

2

C2H4

0.05

C02

2

C2H6

0.05

02

5

C2H2

0.05

n2

5

一一

2.Detector technical indicators:

Thermal conductivity detector (TCD)

Flame Ionization Detector (FID)

Adopt semi-diffusion structure

Cylindrical collector structure, quartz nozzle, extremely high response

The power supply adopts constant current control mode

Automatic ignition; stabilization time: ten minutes

Sensitivity: 10000mV. ml/mg (benzene)

Detection limit: ≤8 x 10-12g/s (n-hexadecane/iso-octane)

Baseline noise: w20uV

Baseline noise: w2x1C) T3a

Baseline drift: ≤l00uV/30min

Baseline drift: ≥2×10-12A/30min

Linearity: ≥104

Linearity: ≥106

3.Temperature control index:

Temperature control part

Temperature control range

Temperature control accuracy

Oven

8℃-400℃ at room temperature

±0.1°C

Hydrogen flame (FID) detector

8℃~400℃ at room temperature

±0.1°C

Thermal conductivity (TCD) detector

8℃~400℃ at room temperature

±0.1°C

Ni catalyst converter

8℃-400℃ at room temperature

±0.1°C


4.Other parameters:

Dimensions: 625 x500 x297mm

Power supply: 220V±22V, 50Hz

Weight: <15kg

Power: ≤600W

II.Technical characteristics

1. Highly integrated integrated design:

The HZ-9760A transformer oil special portable chromatograph adopts a new integrated design. Four gas sources, including nitrogen, hydrogen, air, and standard gas, as well as a computer and a chromatographic workstation are all built into the instrument. There is no need for an external gas source and computer. The box adopts the original imported storm trolley box, and the anti-drop height is more than 1 meter.

2. Three-detector process technology to achieve complete separation of all components:

HZ-9760A transformer oil special portable chromatograph adopts three-detector process technology, equipped with a TCD detector and two FID detectors, which overcomes the influence of a large amount of CO and CC2 on hydrocarbon gases, especially the influence on C2H2, and shortens the detection. At the same time, the detection sensitivity is greatly improved.

3. The carrier gas adopts back pressure control technology, which greatly reduces the influence of injection peaks on hydrogen analysis:

Due to the short peak time of hydrogen, it is more susceptible to the interference of the injection peak. The HZ-9760A transformer oil special portable chromatograph adopts the back pressure valve control technology, which can effectively reduce the interference of the injection peak to the hydrogen peak and reduce the artificial The influence of factors on hydrogen detection greatly improves the accuracy of hydrogen detection.

4. Chromatographic column technology with mixed fillers is used to greatly improve the chromatographic peak response and extend the service life of the chromatographic column:

HZ-9760A special portable chromatograph for transformer oil adopts chromatographic column and ERIC tubing equipped with a new type of mixed packing, which avoids the adsorption of samples to the greatest extent, and increases the response of hydrocarbon gas by about 20 times, and the response of 50ppm ethane The value can reach about 15mv, and the detection limit of ethanediol can reach 0.05ppm.

5. The use of high-sensitivity thermal conductivity detector greatly improves the detection sensitivity of hydrogen:

Different from the traditional thermal conductivity detector, the HZ-9760A transformer oil special portable chromatograph is equipped with a high-sensitivity thermal conductivity detector with a rhenium tungsten wire resistance value of 130 Ω. It has the characteristics of small cell size and fast response. The detection limit can reach 2ppm.

6. Using computer anti-control technology to realize the digital operation and one-key boot of the instrument:

The analysis parameters of the portable chromatograph for HZ-9760A transformer oil, including the setting or display of carrier gas pressure, sample pressure, temperature, etc., are all carried out through the workstation. The operation is simple and the analysis conditions can be grasped in real time. The heating and cooling of the instrument can be realized by clicking the mouse on the workstation, completely abandoning the cumbersome operation in the laboratory chromatogram, and basically realizing a one-key boot.

7. Digital electronic zero adjustment technology to enhance the anti-interference ability of the instrument:

The detector signal zero adjustment of HZ-9760A transformer oil special portable chromatograph adopts electronic zero adjustment technology, uses high-precision digital circuit for base current compensation, realizes electronic adjustment of output signal level, reduces parasitic parameters, and has strong the anti-interference ability.

8. Using computer anti-control technology to realize the control of the oscillator

Through a connection signal line, the HZ-9760A transformer oil special portable chromatograph can provide power for the small oscillator, and can operate the whole process of the oscillator through the workstation, such as heating, starting the oscillation, stopping, and buzzing at the end.

9. Automatic shut-off protection function to ensure the safe operation of the detector

The HZ-9760A transformer oil special portable chromatograph has a gas cut-off protection function. When the carrier gas flow is lower than the set threshold, the instrument will automatically turn off the thermal conductivity current to prevent the thermal conductivity detector from burning and improve the safety of the instrument.

10. The instrument comes with an aging program, and the user can automatically aging the instrument by directly selecting it without complicated settings.

The detector signal zero adjustment of HZ-9760A transformer oil special portable chromatograph adopts electronic zero adjustment technology, uses high-precision digital circuit for base current compensation, realizes electronic adjustment of output signal level, reduces parasitic parameters, and has strong the anti-interference ability.

image012

image014

image016

Request for quote_

Hot Tags: HZ-9760A Portable Gas Chromatograph For Transformer Oil, China, suppliers, manufacturers, price, for sale, gaschromatograph, gas chromatograph machine, hz-9760a, gas chromatograph detector, gas chromatographer

Send Inquiry

(0/10)

clearall