Ti-40 Laboratory Instrument Automatic Potential Titrator
Huazheng Electric Manufacturing (Baoding) Co., Ltd. is one of the leading manufacturers and suppliers of ti-40 laboratory instrument automatic potential titrator in China. Please feel free to buy high quality equipment for sale here from our factory. Good service and reasonable price are available.
Ti-40 Laboratory Instrument Automatic Potential Titrator
Functions
The titration modes include pre-titration, preset end point titration, mode titration, blank titration and manual titration. Different electrodes can be matched with the meter to perform different titrations including acid and alkali titration, oxidation-reduction titration, precipitation titration, complexometric titration and non-aqueous titration. The above titrations are generated into special titration modes such as pre-titration, preset end point titration, blank titration or manual titration. The meter can be communicated with the software. Titration curve can be displayed on the computer to increase the additional value of the meter.

Tech data
1. pH: (0.00~14.00)pH;
mV: (-1800.0~1800.0)mV;
Temp:(-5.0~105.0)℃.
2.Resolution:
pH: 0.01pH; mV: 0.1mV; Temp:0.1℃.
3. Relative accuracy:
pH: ±0.01pH±1 bit; mV: ±0.03% Full Scale; Temp:±0.3℃;
4. Burette volume accuracy 10mlburette:±0.025ml; 20mlburette:±0.035ml.
5. Burette filling solution speed:55±10s(When the burette is in full scale)
6. Reproducibility of titration analysis:0.2%.
7. Relative reproducibility:≤0.2mV.
8. Relative stability:±0.3 mV±1 bit/3h.9.Sensitivity of controlling titration:±2mV.
Maintenance
Ø Keep the sockets of the meter clean and dry. Keep them away from acidity, alkaline, salt solution and also keep them damp-proof to ensure insulation and high input impedance performance of the meter.
Ø When the meter is not used, insert Q9 short circuit plug into the socket of measuring electrode to prevent if from dust and steam.
Ø When the meter is used in the place with higher humidity, dry the plug of the electrode with clean gauze first.
Ø Often clean the whole burette with distilled water, especially the titrant which produces sediment or crystal (eg: AgNO3), clean the burette in time after it is used.
Ø When using perchloric acid Acetic acid as the titrant, keep the ambient temperature higher than 16℃. Otherwise it will produce crystal, and damage the valve.
Troubleshooting table
Number | Failure mode | Failure cause | Solution |
1 | No display after start-up | a.The power is off. b.The fuse is damaged. | a.Check the power b.Replace the fuse of the same type |
2 | mV measurement is not correct. | a.The electrode performance declines. b.The short circuit plug is not good. | a.Replace the new electrode b.Replace the Q9 short circuit plug. |
3 | pH measurement is not correct. | a.Same as the above b.Same as the above c.The electrode socket is set wrongly. | a.Same as the above b.Same as the above c.Set the correct electrode socket according to 6.1. |
4 | Printer does not work or work incorrectly | a.The printer is not connected with the power b.The printer line is not connected c.The printer is set by wrongly d.The printer is wrongly selected. | a.Connect the printer power b.Connect the printer line c.Set the correct printer type according to 6.4. d.Replace the printer. |
5 | Pre-titraion cannot find the end point | a.The end point jump is too small. b.The titrant or sample is wrong. c.The end point volume is small. d.The electrode is wrongly selected. | a.Set the jump grade to 'small' according to 6.7.2. b.Replace the titrant or to sample the correct solution. c.Change the mode to 'blank titration' d.Select electrode correctly. |
6 | Pre-titration has found the false end point | The setup of pre-titration parameter is not suitable. | Set the jump grade to 'large' according to 6.7.2. |
7 | Mode titration is wrong a. Find false end point b. Titration result is 0.000ml c. Can‟t find end point | a.Pre-titration has found the false end point. b.The electrode socket is selected wrongly. c.The mode is selected wrongly. | a.Turn off the false end point according to 15.2.4. b.Set correct electrode socket according to 6.1. c.Select the correct titration mode |
8 | Preset end point titration is wrong a.When the end points are over two, titration cannot be performed after set parameter. b.The meter displays „Pre-controlled point setup is wrong‟ during titration. | a.The parameter setup is wrong. b.The parameter setup is wrong or the electrode socket is set wrongly. | a.Set the correct parameter according to 13.3. b.Set the correct pre-controlled point according to 13.3. c.Set the correct electrode socket according to 6.1 |
9 | The stirrer doesn't work. | a.The stirrer is not connected. b.The stirrer is set wrongly. c.The stirrer is damaged. d.The stirring bar has not been put in the beaker. | a.Connect the stirrer according to 4.1f b.Speed up the stirring rate according to the section 7. c.Replace the stirrer. d.Put the stirring bar. |
10 | There is bubble in filling tube. | Leakage occursin the junction of filling pipe. | Install the filling pipe according to 4.1 c. |
11 | Mechanical part does not work normally. | Burette is not installed correctly. | Install the burette according to 4.1b. |
12 | Electrode is calibrated by mistake. | a.pH electrode performance is bad. b.Buffer is prepared wrongly. c.The eletrode socket is selected wrongly. | a.Replace pH electrode. b.Prepare the buffer again. c.Set the correct electrode socket according to 6.1. |




Hot Tags: Ti-40 Laboratory Instrument Automatic Potential Titrator, China, suppliers, manufacturers, price, for sale, digital automatic potentiometric titration apparatus, Automatic Potentiometric pH/mV Titration System, Automatic Potential Titrator, Automatic Titration for Lab, manual titration equipment, ZDJ4B auto titrator, Automatic Potential Titration System, potential titration set up, automatic titration system, astm d892 foaming tester, Oil Particle Counter Analyzer, oil color tester, calorific value meter, oil interfacial tension tester, Insulating Oil Gas Content Tester