HZJQ-W1 Transformer Oil Withstand Voltage Tester With Infrared Oil Temperature Measurement

HZJQ-W1 Transformer Oil Withstand Voltage Tester With Infrared Oil Temperature Measurement

HZJQ-W1 Insulating oil dielectric strength tester is a high-accuracy tester that has been carefully researched and developed by all the scientific research and technical personnel of our company. Fully digital industrial instruments. The machine is easy to operate and elegant in appearance. Due...
Product Details ofHZJQ-W1 Transformer Oil Withstand Voltage Tester With Infrared Oil Temperature Measurement

 

HZJQ-W1 Transformer Oil Withstand Voltage Tester With Infrared Oil Temperature Measurement


The HZJQ-W1 insulating oil dielectric strength tester is a high-accuracy tester carefully researched and developed by all the scientific research and technical personnel of our company. It is a fully digital industrial instrument. Due to the use of automatic digital computer control, it offers high measurement accuracy, strong anti-interference capability, and safe, reliable operation. Infrared oil temperature measurement is available as a customization option.


Technical indicators

ItemSpecifications
Booster Capacity1.5 kVA
Step-up Speed0.5kV/s~5.0kV/s (adjustable in 0.5kV/s increments, 10 gears optional)
Error: ±0.2kV/s(Note: Supplemented with ± for error standardization)
Output Voltage0~100kV (optional)
Voltage Accuracy±(2% of reading + 2 digits)
Power Distortion Rate<1%
Standard Electrode Gap2.5mm
Test Times6 times (1~9 times optional)
Static Release Time900s (0~9000s optional)
Interval Rest Time300s (0~900s optional)
Mixing Time15s (0~250s optional)


Matters needing attention

1. Before using the instrument, be sure to read this operation manual in detail;

2. The instrument operator should have a general knowledge of the use of electrical equipment or analytical instruments;

3. The instrument can be used in indoor and outdoor, but should avoid rain, corrosive gas, high concentration of dust, high temperature or direct sunlight and otherplaces;

4. Oil cups should be kept clean. During disuse, soak the oil cup with enough dry and qualified insulating oil to keep the oil cup from moisture and electrode oxidation;

5. After one month of continuous use of electrodes, routine inspection and maintenance should be performed. Check and adjust electrode clearance to restore the standard value; Magnifying glass to observe whether there are dark spots on the surface of the electrode, if there is such a phenomenon, wipe the electrode surface with silk cloth, make it restore to its original state;

6. The maintenance and adjustment of the instrument must be done by professional personnel;

7. Before switching on the power supply, carefully check whether the connection line is firm and the instrument shell must be reliably grounded!

8. After the power is switched on, the operator is forbidden to touch the shell of the oil cup lid to avoid the danger of electric shock!

9. When the instrument is in use, if any abnormality is found, the power should be cut off immediately!

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

image014

image016

Request for quote_

Hot Tags: hzjq-w1 transformer oil withstand voltage tester with infrared oil temperature measurement, China, suppliers, manufacturers, price, for sale, surface tension meter with ring, new type transformer oil filter, transformer oil cleaning machine, moisture analyzer karl fischer method, surface tension measuring device, surface tension measurement equipment