HZJF90 Multifunctional Partial Discharge Tester For Switchgear, Transformer, Cable And GIS Test
Huazheng Electric Manufacturing (Baoding) Co., Ltd. is one of the leading manufacturers and suppliers of hzjf90 multifunctional partial discharge tester for switchgear, transformer, cable and gis test in China. Please feel free to buy high quality equipment for sale here from our factory. Good service and reasonable price are available.
HZJF90 Multifunctional Partial Discharge Tester
HZJF90 Handheld partial discharge detector is a portable instrument used to detect partial discharge phenomena in electrical equipment.
Main Technical Parameters
Non-contact Ultrasonic Sensor (AA)
Central frequency of the sensor: 40KHz ± 1KHz
Measurement range: -7~68dBuV
Resolution: 0.1dB
Linearity error: <±20%
Sensor form: Bendable form/Focusing form
Contact Ultrasonic Sensor (AE)
Detection frequency band: 20KHz~80KHz (SF6 gas-insulated power equipment)
80KHz~200KHz (Oil-filled power equipment)
Dynamic measurement range: 60dB
Resolution: 0.1dB
Linearity error: <±20%
Transient Earth Voltage Sensor (TEV)
Detection frequency band: 3MHz~100MHz
Measurement range: 0~60dBmV
Resolution: 0.1dB
Linearity error: <±20%
Ultra-High Frequency Sensor (UHF)
Detection frequency band: 300MHz~1500MHz
Measurement range: -70dBm to -10dBm
Effective sensor height: ≥10mm
Resolution: 0.1dBm
High-Frequency Sensor (HF)
Detection frequency band: 0.3MHz~30MHz
Measurement range: 0~70dB
Gain: -30~20dB
Resolution: 0.1dB
Transmission impedance: ≥10mV/mA
Input impedance: 50Ω
Machine Parameters
Operating environment: Temperature -20℃~50℃, humidity 0~85%
Display screen: High-definition color 5.6-inch TFT LCD display,
resolution 480*640
Mainframe size: 230x170x48mm
Mainframe weight: 1.35Kg
Battery life: About 6 hours
Maintenance And Upkeep
1. Moisture-proof
In humid climate areas or seasons, if the instrument is not used for a long time, it is advisable to turn it on and power it up once a month (about two hours) to dissipate moisture and protect the components.
2. Storage
When not in use, the instrument should be stored in an indoor environment with a temperature of -20~60℃ and a relative humidity below 85%, with ventilation and no corrosive gases.
3. Prevent exposure to direct sunlight
When using it outdoors, operate it in a shaded area as much as possible to avoid or reduce direct exposure of the display screen to sunlight.
4. Charging
The instrument uses a lithium battery as its power supply. If the battery is low, please use the included charger to charge it. Charging time is generally 2 to 4 hours. Charging is not allowed when the instrument is on, and must be done when the instrument is turned off. When charging, the charger indicator light will turn red, and it will turn green when charging is complete. Please use the charger included with the instrument.



Hot Tags: hzjf90 multifunctional partial discharge tester for switchgear, transformer, cable and gis test, China, suppliers, manufacturers, price, for sale, partial discharge detector, partial discharge analyzer, partial discharge testing, Four Channels Partial Discharge Detector, partial discharge detection system, portable partial discharge test equipment
Send Inquiry