HZJF-9041D Four Channels Partial Discharge Detector
HZJF-9041D Four Channels Partial Discharge Detector

Overview
The HZJF-9041D four-channel digital partial discharge detector upgrades the original HZJF-9041 model: it keeps all original advantages, miniaturizes the equipment, optimizes performance, and adopts a 10.1-inch touchscreen instead of traditional oscilloscopes and physical knobs for easier operation.
Main Technical Indicators
1. Model: HZJF-9041D
2. Number of channels: Four channels
3. Measurement range: 0.1pc-10000nc
4. Detection sensitivity and allowable current
| NO. | Tuning Capacitance Range | Sensitivity (PC) (Unbalanced Circuit) | Effective Value Of Allowable Current | |
|---|---|---|---|---|
| Unbalanced Circuit | Balance Circuit | |||
| 1 | 0~25~100pF | 0.02 | 30mA | 0.25A |
| 2 | 25~100~400pF | 0.04 | 50mA | 0.5A |
| 3 | 100~400~1500pF | 0.06 | 120mA | 1A |
| 4 | 400~1500~6000pF | 0.1 | 0.25A | 2A |
| 5 | 1500~6000~25000pF | 0.2 | 0.5A | 4A |
| 6 | 0.006~0.025~0.1μF | 0.3 | 1A | 8A |
| 7 | 0.025~0.1~0.4μF | 0.5 | 2A | 15A |
| 8 | 0.1~0.4~1.5μF | 1 | 4A | 30A |
| 9 | 0.4~1.5~6.0μF | 1.5 | 8A | 60A |
| 10 | 1.5~6.0~25μF | 2.5 | 15A | 120A |
| 11 | 6.0~25~60μF | 5 | 25A | 200A |
| 12 | 25~60~250μF | 10 | 50A | 300A |
Table 1. Detection sensitivity and allowable current value of input unit
5. Elliptic scan time base
(1) Frequency 50/60, 100, 150, 200, 400Hz
(2) Rotation: 30 ° as the first gear, and can rotate 120 °
(3) Working method: ellipse sine wave straight line
6. Display unit
10.1 inch capacitive touch screen is used.
7. Amplifier
(1) 3dB low frequency fl:10, 20, 40KHz optional
(2) 3dB high frequency fh:80, 200, 300kHz optional
(3) Gain adjustment, rough adjustment 6, inter gear gain difference 20 ± 1dB, fine adjustment range >20db
(4) Asymmetry of positive and negative pulse response < 1dB
8. Time window
(1) Window width: adjustable, 5 ° ~ 170 ° at 50Hz
(2) Window position: each window can rotate 0 ° ~ 170 °
(3) Two time windows can be opened separately or simultaneously.
9. Peak pulse display
The touch screen displays 1 decimal place (10pc or more), 2 decimal places (less than 10pc), error: ± 3% (in full scale)
10. Test voltage display
(1) Range 150kV
(2) Input impedance: >1m Ω
(3) Display: touch screen display, display 1 decimal place
(4) Error: ± 1%
11. Test frequency display
Error: less than ± 1%
12. Zero standard system
Zero sign is consistent with all ellipse scanning frequencies
13. Structure
(1) Dimensions: 370mm (width), 460mm (depth), 215mm (height)
(2) Weight: about 12.5kg



Hot Tags: HZJF-9041D Four Channels Partial Discharge Detector, China, suppliers, manufacturers, price, for sale, 4 Channel Partial Discharge Tester, Multi-Channel Partial Discharge Detector, partial discharge detection equipment, Partial Discharge Measurement Device HZJF-9041D, partial discharge detection in high-voltage equipment, partial disharge detector, electrical partial discharge detector, generator partial discharge test device, partial discharge detection equipment, pd tester online, Transformer Oil Purifier Machine, Four Channels Partial Discharge Detector, partial discharge test equipment