+86-312-6775656

HZFD-200 110V 30/50/100/200A Electronic Load Battery Capacity Tester Battery Discharger

Oct 26, 2022

Parameter (Take 110V/30A,110V50A,110V/100A,110V/200A as sample)


Features


Parameters


Model

110V/30A

110V50A

110V/100A

110V/200A


Single voltage test range

2V:0~4V

6V:0~8V

12V:0~15V

2V:0~4V

6V:0~8V

12V:0~15V

2V:0~4V

6V:0~8V

12V:0~15V

2V:0~4V

6V:0~8V

12V:0~15V


Single voltage resolution

2V/6V:0.001V

12V:0.01V

2V/6V:0.001V

12V:0.01V

2V/6V:0.001V

12V:0.01V

2V/6V:0.001V

12V:0.01V


Whole set voltage test range

110V:0~135V

110V:0~135V

110V:0~135V

110V:0~135V


Whole set voltage resolution

0.01V

0.01V

0.01V

0.01V


Voltage test precision

0.5%

0.5%

0.5%

0.5%


Discharging range

 2~30A can be set continuously, over 30A we need the extra loading

2~50A can be set continuously, over 50A we need the extra loading

2~100A can be set continuously, over 100A we need the extra loading

 2~200A can be set continuously, over 200A we need the extra loading


Constant discharging voltage range

110V:90~130V   

110V:90~130V

110V:90-130 V

90-130 V


Discharging control precision

0.1A

0.1A

0.1A

0.1A


Working voltage

AC 220V±15%

 


Radiation


Air cooling


Communication

RS485 Communication and SD card communication


Display

7” colorful LCD touch screen


Overall dim.

440×225×300mm

440×225×300mm

**

***


Weight

﹤20KG

﹤20KG

**

**