Performance Feature
1. The instrument adopts Fourier transform digital filtering technology to measure capacitance, dielectric loss and other parameters. The precision of the test results is high, which is convenient for automatic measurement.
2. The instrument adopts frequency conversion technology to eliminate 50Hz power frequency interference in the field, and reliable data can be measured even in the environment of strong electromagnetic interference.
3. Use full-touch super large LCD, easy to operate. Full touch LCD screen, large full graphical operation interface, each process is clear, operators do not need additional professional training to use. The whole process can be measured with a touch.
4. Data storage: it is equipped with calendar chip and large-capacity memory, which can save the test results at any time, check the history record at any time, and print out. The current time and storage time can be displayed and printed at any time.
5. Scientific and advanced data management: instrument data can be exported through U disk. Data can be viewed and managed by special software on any PC.
6. The instrument is easy to operate, and the measurement process is controlled by the microprocessor. As long as the appropriate measurement method is selected, the data measurement can be completed automatically under the control of the microprocessor.
7. Integrated model, with standard capacitor and high-voltage power supply, facilitates field testing and reduces field wiring.
8. The measurement accuracy of the instrument is high, which can meet the requirements of oil dielectric loss measurement. Therefore, the measurement of oil dielectric loss can be achieved only by equipping standard oil cup and special test line.
9. It has reverse wiring low-voltage shielding function. When the 220kV CVT bus is grounded, 10kV reverse wiring dielectric loss measurement can be performed on the C11 without removing the wires.
10. Able to do ac withstand test. It is convenient for PT, CT secondary side ac withstand voltage, 400V low-voltage system to do the withstand voltage test.
11. It can identify the frequency of external high voltage power supply (40Hz~70Hz), and allow the use of frequency power supply or serial resonant power supply to conduct large-capacity and high-voltage dielectric loss test.
12. With CVT test function, CVT self-excitation test can be realized, and 4 protection limits of high voltage/current and low voltage/current can be set to ensure the safety of person and equipment.
13. When testing CVT, not only the capacitance and dielectric loss values of C1 and C2 can be automatically tested, but also the total capacitance and dielectric loss values of CVT equipment can be tested
14. Equipped with thermal printer for printing and output, with calendar clock, convenient for users to produce test report, with U disk output.
15. With a computer interface. A computer can control 32 instruments, which can be integrated into the comprehensive high-voltage test vehicle to achieve measurement, data processing and report output.
16. Grounding protection function, when the instrument is not grounded or the grounding is bad, the instrument does not enter the normal program, does not output high voltage. Over-current protection, the instrument will not be damaged in short circuit or breakdown.
17. Electric shock protection function: when the operator of the instrument accidentally touches the electric shock, the instrument will immediately cut off the high voltage to ensure the safety of the test personnel.
Technical Indicators
Accuracy: Cx: ±(readings×1%+1pF)
tgδ: ±(readings×1%+0.00040)
Anti-interference index: frequency conversion anti-interference, can still achieve the above accuracy under the interference of 200%.
Capacitance range:
Internal high voltage:3pF~60000pF/12kV 60pF~1μF/0.5kV
External high voltage: 3pF~1.5μF/12kV 60pF~30μF/0.5kV
Resolution: up to 0.001 pF, 4-bit significant digits
Tgδ range: no limi,The resolution is 0.001%. The capacitance, inductance and resistance can be identified automatically.
Test current range:10μA~5A
Internal high voltage:
Setting Voltage Range:0.5~12kV
Maximum output current:200mA
Boost and drop voltage mode: the voltage is set at will. Such as 5123 v.
Test frequency: 40-70Hz single frequency can be set at will. For example, 48.7 Hz.
50± 0.1Hz to 50±10Hz automatic dual frequency conversion optional setting.
60± 0.1Hz to 60±10Hz automatic dual frequency conversion optional setting.
Frequency accuracy: ±0.01Hz
External high voltage: maximum test current 5A, power frequency or frequency conversion of 40-70Hz during positive connection
Maximum test current 10kV/5A, power frequency or frequency conversion 40-70Hz
CVT self-excitation method low voltage output: output voltage 3~50V, output current 3~30A
Measurement time: about 40s, related to measurement method
Input power: 180V ~ 270VAC, 50Hz±1%, municipal or generator power supply
Computer interface: standard RS232 interface, U disk socket (automatic U disk storage data).
Printer: micro thermal printer
environment temperature: -10℃ ~ 50℃
relative humidity: <90%
Overall dimension: 430×330×350mm
Weight: 28kg