What is zinc oxide arrester and its function

Feb 07, 2023

The zinc oxide arrester is assembled in the zinc oxide valve, and the zinc oxide valve plate has good nonlinear volt-ampere, is in the insulation state under the normal working voltage, and has a high resistance value under the action of lightning overvoltage. Then, in the low resistance state, the residual voltage of the electrical equipment in parallel with the lightning arrester is suppressed below the safe value of the equipment insulation due to the lightning discharge. After the harmful overvoltage disappears, the valve plate quickly recovers to high resistance and is in insulation state, thus protecting the insulation of electrical equipment and avoiding voltage damage. The ruthenium in the zinc oxide hair follicle composite insulation layer has good electrical insulation performance, high dielectric strength

Zinc oxide lightning arrester is a kind of lightning arrester with good protection. The current flowing through the arrester under normal working voltage (microamps or milliamps) is measured by using the good nonlinear voltammetry of zinc oxide; When overvoltage is activated, the resistance drops sharply and the energy of overvoltage is released. Achieve protection effect. The difference between this kind of arrester and traditional arrester is that the non-discharge gap will use the non-linear characteristics of zinc oxide to discharge and open circuit.

1. An instrument used to protect electrical equipment from high transient overvoltage during lightning stroke, limit the current duration and often limit the current distribution value. Lightning arrester is sometimes called overvoltage protector or overvoltage limiter.

2. The lightning arrester is connected between the cable and the earth, usually in parallel with the protected equipment. Lightning arrester can effectively protect communication equipment. In case of abnormal voltage, the lightning arrester will act to protect the equipment. When the communication cable or equipment operates under the normal working voltage, the lightning arrester does not work and is considered as the grounding circuit breaker. When the insulation of the protected equipment is endangered, the lightning arrester will act immediately to impact the high voltage to the ground, limit the voltage amplitude, and protect the insulation of the communication cable and equipment. When the overvoltage disappears, the lightning arrester quickly returns to its original state, enabling the communication line to work normally.

Arrester Tester

Huazheng Electric specializes in the production of zinc oxide arrester characteristic tester, and welcomes customers to purchase