Electrical Safety Hand Gloves Test Machine
Huazheng Electric Manufacturing (Baoding) Co., Ltd. is one of the leading manufacturers and suppliers of electrical safety hand gloves test machine in China. Please feel free to buy high quality equipment for sale here from our factory. Good service and reasonable price are available.
Huazheng Electrical Safety Hand Gloves Test Machine
Instrument function
This gloves test machine is primarily designed for AC voltage testing of commonly used electrical insulation tools. The operation box comes with preset test parameters for insulating boots, insulating gloves, and insulating rubber pads in accordance with national standards. Specific parameter details are provided in the following table.
Executive Standard
|
No. |
Standard name |
|
1 |
DL/T 676-2012 General technical conditions for insulating shoes (boots) for live working |
|
2 |
GB 12011-2009 Foot protection Electrically insulated shoes |
|
3 |
HG 2949-1999 electric insulation rubber sheet |
|
4 |
GB/T 17622-2008 Insulated gloves for live working |
|
5 |
GBJ 150 Electrical Equipment Installation Engineering Electrical Equipment Handover Test Standard |
|
6 |
GB/T 8218-1987 Low-voltage measuring appliance |
Instrument characteristics
1. Automatic & Fast Testing
Stepper motor controls boosting process
Auto boost, soak, reduction per national standards
Timing starts at pre-set voltage; auto cutoff at zero
Displays leakage current and test results
2. Comprehensive Functions
Full English interface with status display
Rotary mouse for all settings
Full digital adjustment (no potentiometers)
Direct parameter setting: voltage, leakage, time
3. Intelligent Safety Protection
Overcurrent and overvoltage protection
Rapid, accurate response for personnel/equipment safety
4. Flexible Output
Voltage: 1–30 kV (customizable)
Leakage current: 1–20 mA
Test time: 1–10 min
Pre-set modules for standard insulation equipment
5. User-Friendly Interface
320×240 white-backlit LCD; visible in strong light
High-performance rotary mouse
Built-in high-speed micro-printer
Product parameters
|
Insulation boot test |
Voltage |
25kV |
|
Leakage current |
≤10mA |
|
|
Time |
1min |
|
|
Resolution |
0.1kV,0.1mA |
|
|
Accuracy |
Voltage ±(2%+3d)Current ±(2%+3d)3 words) |
|
|
Insulation gloves test |
Voltage |
High voltage:8kV Low voltage 2.5kV |
|
Leakage Current |
≤9mA |
|
|
time |
1min |
|
|
Resolution |
0.1kV,0.1mA |
|
|
Accuracy |
Voltage ±(2%+3d)Current ±(2%+3d)words) |
|
|
Insulation rubber pad test |
Voltage |
High voltage:15kV Low voltage:3.5kV |
|
Leakage Current |
No breakdown |
|
|
Time |
1min |
|
|
Resolution |
0.1kV,0.1mA |
|
|
Accuracy |
Voltage ±(2%+3d)Current ±(2%+3d)3 words) |
|
|
Custom test |
Voltage |
1-30kV |
|
Leakage Current |
1-20mA |
|
|
Time |
1-10min |
|
|
Resolution |
0.1kV,0.1mA |
|
|
Accuracy |
Voltage ±(2%+3d)Current ±(2%+3d)3 words) |
|
|
Working power |
AC220V 50HZ |
|
|
The output voltage |
0-30kV |
|
|
Capacity |
3kVA |
|
|
test numbers |
6 pcs/times |
|
|
Ambient temperature |
-10℃ ~ +50℃ |
|
|
Operation box dimension |
35*22*37cm |
|
|
Operation box weight |
12kg |
|
|
Test car dimension |
75*90*102cm |
|
|
Test car weight |
60kg |
|
Operating points
1. Water Test Setup for Insulating Boots (Gloves)
Remove the sponge prior to the water test. Fill both the inside and outside of the insulating boots (gloves) with water to the same level, leaving approximately 90 mm of the test sample exposed above the water surface. Ensure that the exposed portions are dry and clean. Then, place the high-voltage electrode inside the insulating boots (gloves) and secure the sample with the clamp.
2. Steel Ball Test Method
When testing insulating boots with steel balls, add water to the water tank until the sponge is fully immersed. Place a metal piece corresponding to each boot being tested into the boot. Insert the high-voltage electrode into the insulating boot so that it contacts the metal piece. Then, cover the metal piece with steel balls having a diameter not exceeding 4 mm, to a height of no less than 15 mm.
3. Site Setup & Safety Supervision
Set up the test site in accordance with relevant regulations and complete all equipment wiring connections. A designated safety supervisor shall be present in the testing area to provide guidance and ensure compliance with safety protocols.
4. Grounding Requirements
The console contains high-voltage circuitry, with the high-voltage terminal and high-voltage lead routed to the rear panel. To ensure operator safety, the ground terminal of the console must be reliably and securely grounded.




Hot Tags: electrical safety hand gloves test machine, China, suppliers, manufacturers, price, for sale, electric gloves test machine, electrical glove testing equipment, Integrated glove testing system, dielectric gloves test set, glove test device, latex gloves test device