+86-312-6775656
Electrical Safety Hand Gloves Test Machine

Electrical Safety Hand Gloves Test Machine

Electrical rubber gloves test machine Instrument function This instrument is mainly used for AC voltage test of commonly used electrical insulation tools. Among them, the operation box has been preset the test parameters of insulating boots, insulating gloves, insulating rubber pads according to national standards. The specific...
Product Details ofElectrical Safety Hand Gloves Test Machine

Huazheng Electric Manufacturing (Baoding) Co., Ltd. is one of the leading manufacturers and suppliers of electrical safety hand gloves test machine in China. Please feel free to buy high quality equipment for sale here from our factory. Good service and reasonable price are available.

 

Huazheng Electrical Safety Hand Gloves Test Machine

 

Instrument function

This gloves test machine is primarily designed for AC voltage testing of commonly used electrical insulation tools. The operation box comes with preset test parameters for insulating boots, insulating gloves, and insulating rubber pads in accordance with national standards. Specific parameter details are provided in the following table.

 

Executive Standard

No.

Standard name

1

DL/T 676-2012 General technical conditions for insulating shoes (boots) for live working 

2

GB 12011-2009 Foot protection Electrically insulated shoes

3

HG 2949-1999 electric insulation rubber sheet

4

GB/T 17622-2008 Insulated gloves for live working

5

GBJ 150 Electrical Equipment Installation Engineering Electrical Equipment Handover Test Standard

6

GB/T 8218-1987 Low-voltage measuring appliance

 

Instrument characteristics

1. Automatic & Fast Testing

Stepper motor controls boosting process

Auto boost, soak, reduction per national standards

Timing starts at pre-set voltage; auto cutoff at zero

Displays leakage current and test results

2. Comprehensive Functions

Full English interface with status display

Rotary mouse for all settings

Full digital adjustment (no potentiometers)

Direct parameter setting: voltage, leakage, time

3. Intelligent Safety Protection

Overcurrent and overvoltage protection

Rapid, accurate response for personnel/equipment safety

4. Flexible Output

Voltage: 1–30 kV (customizable)

Leakage current: 1–20 mA

Test time: 1–10 min

Pre-set modules for standard insulation equipment

5. User-Friendly Interface

320×240 white-backlit LCD; visible in strong light

High-performance rotary mouse

Built-in high-speed micro-printer

 

Product parameters

Insulation boot test

Voltage

25kV

Leakage current

≤10mA

Time

1min

Resolution

0.1kV,0.1mA

Accuracy

Voltage ±(2%+3d)Current ±(2%+3d)3 words)

Insulation gloves test

Voltage

High voltage:8kV  Low voltage 2.5kV

Leakage Current

≤9mA

time

1min

Resolution

0.1kV,0.1mA

Accuracy

Voltage ±(2%+3d)Current ±(2%+3d)words)

Insulation rubber pad test

Voltage

High voltage:15kV  Low voltage:3.5kV

Leakage Current

No breakdown

Time

1min

Resolution

0.1kV,0.1mA

Accuracy

Voltage ±(2%+3d)Current ±(2%+3d)3 words)

Custom test

Voltage

1-30kV

Leakage Current

1-20mA

Time

1-10min

Resolution

0.1kV,0.1mA

Accuracy

Voltage ±(2%+3d)Current ±(2%+3d)3 words)

Working power

AC220V 50HZ

The output voltage

0-30kV

Capacity

3kVA

test numbers

6 pcs/times

Ambient temperature

-10℃ ~ +50℃

Operation box dimension

35*22*37cm

Operation box weight

12kg

Test car dimension

75*90*102cm

Test car weight

60kg

 

Operating points

1. Water Test Setup for Insulating Boots (Gloves)
Remove the sponge prior to the water test. Fill both the inside and outside of the insulating boots (gloves) with water to the same level, leaving approximately 90 mm of the test sample exposed above the water surface. Ensure that the exposed portions are dry and clean. Then, place the high-voltage electrode inside the insulating boots (gloves) and secure the sample with the clamp.

2. Steel Ball Test Method
When testing insulating boots with steel balls, add water to the water tank until the sponge is fully immersed. Place a metal piece corresponding to each boot being tested into the boot. Insert the high-voltage electrode into the insulating boot so that it contacts the metal piece. Then, cover the metal piece with steel balls having a diameter not exceeding 4 mm, to a height of no less than 15 mm.

3. Site Setup & Safety Supervision
Set up the test site in accordance with relevant regulations and complete all equipment wiring connections. A designated safety supervisor shall be present in the testing area to provide guidance and ensure compliance with safety protocols.

4. Grounding Requirements
The console contains high-voltage circuitry, with the high-voltage terminal and high-voltage lead routed to the rear panel. To ensure operator safety, the ground terminal of the console must be reliably and securely grounded.

safety tools  test set

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

Customer Visit

Case

Request for quote_

Hot Tags: electrical safety hand gloves test machine, China, suppliers, manufacturers, price, for sale, electric gloves test machine, electrical glove testing equipment, Integrated glove testing system, dielectric gloves test set, glove test device, latex gloves test device

Send Inquiry

(0/10)

clearall