HZAQ-KS High Voltage Insulating Gloves Dielectric Test Equipment

HZAQ-KS High Voltage Insulating Gloves Dielectric Test Equipment

HZAQ-KS High Voltage Insulating Gloves Dielectric Test Equipment image of factory Products Overview Insulated gloves are the necessary safety equipment for power system operation and maintenance DL / T1476 Regulations for preventive test of electrical appliances for safety of electric industry the test...
Product Details ofHZAQ-KS High Voltage Insulating Gloves Dielectric Test Equipment

High Voltage Insulating Gloves Dielectric Test Equipment

dielectric gloves tester

image of factory

Products Overview

Insulated gloves are the necessary safety equipment for power system operation and maintenance DL / T1476 Regulations for preventive test of electrical appliances for safety of electric industry the test method and cycle of common safety equipment such as insulating boots and gloves are stipulated.Insulated boots and gloves voltage test, the cycle is half a year, the test process is not allowed to break down, Simultaneously insulated boots leakage current is less than the limit value.

The instrument adopts multi-channel high voltage leakage current measurement patent technology and infrared data communication technology to achieve the safe measurement of high voltage leakage current purposes.Through the application of this technology, the tester is completely isolated from the high-voltage system, which can not only accurately measure the multi-channel high-voltage leakage current, but also ensure the personal safety of tester.

Technical parameters

Rated capacity:10kVA

Output voltage range:100.0 kV(250V)

Voltage measurement error:<±(0.5 %U+0.02%Umax),

Where U is the indication value and Umax is the upper limit value of the range.


Input current process:50.0A

Current measurement error:<±(0.5%I+0.02%Imax),

Where I is the indication value and Imax is the upper limit value of the range

Divider:

Voltage divider ratio:100/0.1(kV)

Variable-ratio error of voltage divider:1.5%

Insulating gloves test bench:

Test position: 8

Leakage current path:25.0mA

Leakage current measurement error:±(1%I+2 words)

Leakage current resolution:0.1 mA

Insulation Rod Test bench:

Test voltage:100kV

Test stations: 8

Insulation rod support height:1.2 M

Range of regulation:300 ~ 1030(mm)

Insulation pad test bench:

Test bed area:1000*1000( mm )

Electrode area:800*800(mm)

Composition of equipment

3.1 HZAQ-KS console

(This article is referred to as the console for short) 1 Unit

3.2 HZAQ-YW automatic dielectric gloves tester

(This article is referred to as the high pressure discharge measuring and controlling instrument)

1 Set

3.3 HZYD-10/100 inflatable test transformer 1 Set

3.4 HZAQ-YG insulated rod tester 1 Set

3.5 HZAQ insulated mat tester 1 Set

3.6 Computers(Installed on the console) 1 Set

Related recommended products

glove test

Huazheng Electric Manufacturing

Customer Visit

Case

Request for quote_

Hot Tags: HZAQ-KS High Voltage Insulating Gloves Dielectric Test Equipment, China, suppliers, manufacturers, price, for sale, insulating gloves testing setup, Dielectric Gloves Tester, electrical gloves testing frequency, dielectric testing of rubber gloves, Dielectric Gloves Test Bench HZAQ-KS, Electrical Glove Testing Service, hipot tester for boots gloves