Repair steps of battery activation instrument

Apr 06, 2021

The battery activator is a battery repair and maintenance equipment. After testing and selecting outdated batteries, we still have an important thing to do, that is, to restore the capacity of the outdated batteries as much as possible. Therefore, there is the stage of activation instrument. Generally, most of the battery failures in communication units are due to the decrease of capacity due to the crystallization of the plate. The battery activator is used to charge and discharge the battery with high current to melt the crystal to activate the chemical substances. Generally, the capacity can be restored to more than 90% of its rated capacity after activation. However, it is worth noting that not any backward battery can be activated. The battery activator can only adapt to some of the backward causes of chemical failures. As for the physical failure of the activator, there is no way to repair it, such as Said that the plates are shorted and so on.


So what are the specific repair steps of the battery activation instrument?


In the first step, the battery activation tester judges the bad battery. The probe is mainly used to check grid by grid when there is a discharge load.

 

The second step is to determine whether it can be repaired. The method is: connect the entire battery to the discharge load and observe the voltage drop of the bad cell:

 

1. If the voltage drops to about 0V quickly, and no longer drops, and the bad cell is accompanied by hot spots, the voltage does not rise or rises very slowly after removing the discharge load, it can be initially judged as a short circuit, and other methods can be used to repair;

 

2. If the single-cell voltage drops to 0V and continues to decrease, negative voltage or reverse polarity appears. After the discharge load is removed, the single-cell voltage quickly rises to other good levels. We can judge that the single-cell can be repaired;

 

The third step is to punch the battery. Prepare a drill and a 2mm diameter drill bit, and prepare two self-tapping screws with a length of 4cm-5cm and a diameter of about 3mm. The tip of the self-tapping screw should be dull with a file (file the tip flat), and at the same time, the self-tapping screw head The 3cm part of the part is plated with solder with an electric soldering iron;

 

The fourth step is to repair.

 

Single cell with reverse polarity after the discharge load is connected, adopts single cell activation treatment.


Send Inquiry