The calorific value detection of chemical products is usually measured through direct combustion or simulated combustion processes. The following are several common detection methods:
Oxygen bomb calorimetry: This is the most commonly used method for detecting the calorific value of chemical products. The sample is burned in an oxygen bomb calorimeter, and the calorific value is calculated by measuring the heat generated during combustion, which is suitable for the detection of solid and liquid fuels.
Combustion heat analysis: using devices such as differential scanning calorimetry (DSC) or thermogravimetric analyzer (TGA) to measure the heat release during the combustion process of a sample under controlled conditions, commonly used for evaluating the calorific value of small samples or special materials.
Smoke analysis method: By measuring the content of CO2, CO and other components in the smoke during the combustion process, and combining it with a theoretical combustion model to calculate the combustion heat value, it is suitable for the detection of gaseous fuels.
Near infrared spectroscopy (NIR): This method calculates the calorific value of chemical products by analyzing their near-infrared spectra. It is commonly used for rapid analysis and online monitoring, and is suitable for fuel detection in continuous production processes.
Method for testing the calorific value of chemical products
Nov 03, 2024
Send Inquiry