Infrared Spectrometer For Oil Content In Water Analyzer
Huazheng Electric Manufacturing (Baoding) Co., Ltd. is one of the leading manufacturers and suppliers of infrared spectrometer for oil content in water analyzer in China. Please feel free to buy high quality equipment for sale here from our factory. Good service and reasonable price are available.
Infrared Spectrometer For Oil Content In Water Analyzer
Scope of application:
This instrument is suitable for the detection of total oil, petroleum or animal and vegetable oil content in various water bodies such as surface water, groundwater, industrial wastewater, domestic sewage, seawater, fishery water, farmland irrigation water, etc. The testing and testing principles are in full compliance with the current testing standards for the above-mentioned various industries or water bodies.
Detection principle:
According to the HJ637-2018 standard, the oil in the sample was extracted with tetrachloroethylene to determine the total oil, and then the extract was adsorbed with magnesium silicate to remove polar substances such as animal and vegetable oils, and then the petroleum was determined. The contents of total oil and petroleum are determined by wavenumbers of 2930 cm-1 (stretching vibration of CH bond in CH2 group), 2960 cm-1 (stretching vibration of CH bond in CH3 group) and 3030 cm-1 (stretching vibration of CH bond in aromatic ring), respectively. Bond stretching vibration) absorbance at the bands A2930, A2960 and A3030 were calculated. The content of animal and vegetable oils is calculated as the difference between the total extract and the content of petroleum.
Parameter index:
Baseline stability: real-time automatic correction of zero point, no effect of baseline drift
2. The detection limit of the method: 0.01mg/L (when the sample volume is 1000mL, the extract volume is 25mL, and the optical path of the cuvette is 40mm)
0.04mg/L (sample volume 500mL, extract volume 50mL, cuvette optical path 40mm)
3. Minimum detectable concentration: 0.001mg/L
4. The highest measured concentration: 640000mg/L
5. Basic measuring range: 0~800mg/L
6. Accuracy error: ≤2%
7. Repeatability error: RSD≤0.6% (30~40mg/L oil sample was measured 11 times)
8. Linear correlation coefficient: R>0.999
9. Wave number range: 3400cm-1~2400cm-1 (2940nm~4167nm)
10. Wavenumber accuracy: ±2cm-1
11. Wavenumber repeatability: ±2cm-1
12. Absorbance range: 0.00000~2.00000AU (ie transmittance 100~1%T)
13. Scanning speed: 30 seconds/time for full spectrum scanning, 2 seconds/time for non-dispersive infrared method



Hot Tags: infrared spectrometer for oil content in water analyzer, China, suppliers, manufacturers, price, for sale, astm d1298 oil density meter, bomb calorimeter coal analysis, brake fluid boiling point tester, oxygen bomb calorimeter, astm d1500 color meter, Transformer Oil Density Meter
Send Inquiry