Transformer Capacity Dissipation Factor Empty Load and Load Tester
Product Introduction
From raw materials to finished products, each of our dga test of transformer oil, sf6 gas analyser, acdc test transformer has undergone rigorous testing in terms of safety and efficiency. Our company takes customer problem-solving as the basic orientation, transposition thinking as the basic method and professional technology and high-quality products as the solid backing. With our experienced engineering team and strong inventory capacity, we provide perfect solutions and attentive services at every stage from design, development, certification, production, quality control, shipment to after-sales. In today's rapid development of information technology, our company needs to use information technology to maintain the relationship with customers. We define our goals, improve our systems, and set and achieve challenging objectives.
HZ-6300C Transformer Capacity And Loss Characteristic Tester
Summary

Technical Data
The output range of built-in battery | |
Voltage | 0~10V |
Current | 0~10A |
The output range of test battery | |
Voltage | 0~750V |
Current | 0~100A |
Precision | |
Voltage, current | ±0.2% |
Power | ±0.5%(CosΦ>0.1), ±1.0%(0.02<CosΦ<0.1) |
Volume | 32×25×12 |

Note
1. The connecting method of testing line should operate according to instruction, otherwise it will affect the result
2. The wiring should be proceeded when the testing line has grounded in order to electric shock of induced voltage.
3. Please ensure the voltage ,current under the testing range. It need to connect with CT PT to expand the range, or testing result will not right.
4. When instrument do capacity test, active load test, load test,
Please ensure the short circuit of the no-pressure side, otherwise it will affect the result.
5. When doing the load test, if there is the power casing of HV LV side(Eg: CT), Please ensure short circuit of secondary winding of CT.



Relying on our persistence, pursuit and courage to challenge ourselves forever, we will continue to bring forth the new and create better Transformer Capacity Dissipation Factor Empty Load and Load Tester to thank new and old customers for their support. Our products are all based on the principle of authenticity, and our market share has been increasing. 'Seeking quality, innovation and better' is our policy, and 'keeping promises and common development' is our aim.
Hot Tags: HZ-6300C Transformer Capacity and Loss Characteristic Tester, China, suppliers, manufacturers, price, for sale, Transformer Capacity and Load Tester, Transformer Capacity Test Equipment, transformer capacity characteristic test instrument, transformer capacity and characteristic test system, hz6300c, hz-6300c, transformer capacity loss test machine, transformer capacity loss parameters tester, Transformer Capacity And No-load Tester, induced ac withstand voltage test, winding resistance tester 3 phase, impulse withstand voltage test, cable fault pinpoint locator, tan delta test equipment, complete transformer test system