+86-312-6775656
Test Equipment Transformer Winding Resistance Test Set

Test Equipment Transformer Winding Resistance Test Set

DC resistance of transformer is one testing item which must be tested during ex-work test of semi-finished products and final products, installation, acceptance test and preventive test of electric power department
Send Inquiry
Product Details of Test Equipment Transformer Winding Resistance Test Set

Product Introduction

We have established a comprehensive quality, environmental, and occupational health and safety management system to ensure that the primary current injection test machine, sfra transformer testing equipment, SF6 Gas Purity Analyzer and services we provide are of first-class level and quality. With our dedicated team of specialist, we firmly believe in providing the best products for your needs at the price most suitable for your budget. The product variety is complete and the price is reasonable. We bring long-term, sustainable value to our shareholders by protecting and fully and efficiently utilizing the company's assets.

HZ-3320D DC Winding Resistance Tester 20A 3 channels

3 Channel DC Winding Resistance Tester

Summary

DC resistance of transformer is one testing item which must be tested during ex-work test of semi-finished products and final products, installation, acceptance test and preventive test of electric power department, which can effectively find out material selection of transformer coil, welding, looseness of connection part, missing strand, broken wire etc manufacturing defect and existing hidden problems after operation. In order to meet rapid measurement demand of transformer DC resistance, HZ-3320D DC Winding Resistance Tester 20a 3 channels applies new power technology, which is characterized with small volume, light weight, big output current etc. The whole machine is controlled by a single chip microcomputer, which has automatic self-inspection, data process, display etc functions, it also has automatic discharge and discharge audio alarm and indication etc functions. Testing accuracy of instrument is high, operation is easy and simple, and it can realize rapid measurement of transformer DC resistance.


Tech Data

Output current

0~20A (Automatic select according to measuring scope)

Measuring range

0~50Ω

Accuracy

0.2%±0.5μΩ

Resolution

0.1μΩ

Working temperature

-20~40℃


HZ-3320D_02HZ-3320D_03

HZ-3320D_05

Common Problems And Solution Methods

1. Don't start and buzzer continues sound

Firstly check whether power supply is connected with AC380V or voltage of input power supply is too low under such condition.

2. Crystal screen can't be lit when machine is started.

Firstly check whether power supply is normal in case of this situation, then check whether fuse is broken. If it is broken, replace new fuse.

3. Liquid crystal screen for starting machine is lit but display is abnormal or not display

Firstly start again and press re-set key once under such condition.

4. Testing data isn't stable or error is too great

Firstly check testing wire whether it is virtually connected and loose under such condition. If it isn't still solved, check whether the sample is corroded.

5. Always display "Charging …." during testing process

Firstly exclude magnetic circuit problem of the transformer in case of this situation. If the current isn't changed for long time and it is always around zero, check whether there is short circuit phenomenon in the circuit. If current isn't always charged, check whether measurement scope is exceeded.

6. "Exceed measurement scope". If resistance value is greater than 50Ω during testing process, it will inform "Exceed measurement scope", the instrument will not stop testing, and it will continue display testing result. But the measurement result may be inaccurate, it belongs normal phenomenon.

7. "Overheat protection" Temperature may rise up because the power supply in the instrument works for long time or is damaged, it will inform "Overheat protection". Start the machine and don't carry out testing, let the air fan work for 10 minutes and let internal temperature drop down as soon as possible, and then carry out testing. If it can't be tested, power supply may be damaged.

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

image016

image018

Request for quote_

Our company constantly strengthens the construction of innovation base for invigorating trade through science and technology and supports the export of Test Equipment Transformer Winding Resistance Test Set with independent brands and intellectual property rights. Our highly advanced infrastructure facility has enabled us to furnish the numerous preferences and necessities of our precious patrons in a well-defined manner. By taking part in the competition through technological innovation and accumulation, we are now seeking high-level excellence and perfection in organizational systems and corporate culture.

Hot Tags: HZ-3320D 3 Channel DC Winding Resistance Tester, China, suppliers, manufacturers, price, for sale, 3-Phase Transformer Winding Resistance Meter, Three Channel Winding Resistance Tester, Three Channel Winding Resistance Test Set, Three Phase DC Resistance Measurement, HZ-3320D, hz3320d, 3 circuit dc resistance tester, Three phase transformer DC resistance tester, 20a winding 3 phase resistance tester, distribution transformer test bench, huazheng hzjq 1b trasformer oil bdv tester, ice point tester, Comprehensive Transformer Test System, ac resonant test system 1000kva, liquid particle counter

[[ProKeywords]]

SPEC DATA

Send Inquiry

Send a Message