+86-312-6775656
Gfuve Multifunction Transformer Turn Ratio TTR Tester with High Accuracy

Gfuve Multifunction Transformer Turn Ratio TTR Tester with High Accuracy

During the processing of the semi-finished products and the finished products in transformer production, the transformer newly installation before using, or according to IEC and national standard, the turns ratio or voltage ratio should be tested in the circle rate.
Send Inquiry
Product Details of Gfuve Multifunction Transformer Turn Ratio TTR Tester with High Accuracy

Product Introduction

We adhere to the insulating oil purifier, insulating oil dielectric strength tester, hipot test transformer business as the center, with the goal of improving the overall benefits of customers, and we are dedicated to providing fast, economical and thoughtful services to domestic and foreign customers. We improve skills, promote productivity, reduce drudgery and improve the quality of life of our employees. Our company has advanced hardware facilities, strong research and development strength and technical advantages. Our company has strong technical force and rich processing experience, which is suitable for the production of large and small batch products.

HZTTR80A Transformer Turn Ratio Tester


Panel Description

hzttr80a Turn Ratio Tester

1. Grounding Terminal: Before conducting any tests, please safely ground the grounding terminal to avoid the risk of electric shock.

2. Power Socket and Switch: The power input port for the entire device, used to connect or disconnect the test power supply.

3. High-voltage side connection terminals: There are three-color (yellow, green, red, and black, with the black one being counted as part of the color indication context here for understanding the connection mapping, though technically it's a single additional color column beyond the three primary phase colors) binding posts, corresponding to connection with the A, B, C, N phases of the high-voltage side of the transformer being measured.

4. Low-voltage side connection terminals: There are three-color (yellow, green, red, and black, similarly, the black one is included in the context for connection mapping explanation) binding posts, corresponding to connection with the a, b, c, n phases of the low-voltage side of the transformer being measured.

5. High-Voltage Side Terminals: Yellow, green, and red terminals for connecting to the A, B, and C phases of the high-voltage side of the transformer under test.

6. Low-Voltage Side Terminals: Yellow, green, and red terminals for connecting to the a, b, and c phases of the low-voltage side of the transformer under test.

7. RS232 Communication Interface: Interface for computer communication.

8. Printer: Prints test results.

9. USB: Connects to a USB flash drive for data export.

10. Display Screen: 7-inch high-definition color touchscreen LCD with adjustable backlight for displaying the operation menu and test results.


HZBB-10A Turn Ratio Tester

HZBB-10A Turn Ratio Tester


Technical Index

Test Range: Transformation Ratio -- 0.9 to 10000, Current -- 0 to 2000mA, Angle -- 0 to 360°

Ratio Accuracy:
5V Range: ±(0.1% + 2 digits) (0.9-50), ±(0.2% + 2 digits) (51-200), ±(0.5% + 2 digits) (201-600)
80V Range: ±(0.1% + 2 digits) (0.9-500), ±(0.2% + 2 digits) (501-2000), ±(0.5% + 2 digits) (2001-10000)
Current Accuracy: ±(1% of reading + 0.5 mA)
Angle Accuracy: ±0.2°
Output Voltage: Selectable 5V or 80V
Resolution: Ratio -- Minimum 0.0001, Current -- 0.001mA, Angle -- 0.01°
Test Voltage: AC 5V @ 1A, AC 80V @ 80mA
Operating Power Supply: The maximum power is 50W


Troubleshooting and Maintenance

If any abnormalities occur during the use of the tester, please follow the steps below for troubleshooting:

1. If the measurement data is abnormal, please check if the wiring is correct. If it is still abnormal, you can perform a self-test using the following method. The wiring is shown in the figure below:After connecting the wires, select any three-phase connection method for testing. If the measured value is approximately 1.0000, the instrument is functioning normally; otherwise, there is an issue with the instrument. If no shorting wire is available, you can also short-circuit the high-voltage side yellow, green, and red wire clamps to the corresponding low-voltage side yellow, green, and red wire clamps.

2. If the tester does not respond when turned on and the display screen is not lit, please check if the power fuse inside the panel is blown.

3. If it is confirmed to be an internal fault of the tester, please contact our company immediately, and we will resolve it as soon as possible.


hzbb10A ttr tester

Packing list


No.

Item

Qty

1

Host

1

2

Test Cables

1

3

Power Cord

1

4

Operation Manual

1

5

Certificate of Conformity

1

6

Fuse

2

7

Printing Paper

1

8

Packing List

1

9

Ground wire

1

HZTTR80A


lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

image014

image016

Request for quote_

Our company's processes are complete and legal, and our Gfuve Multifunction Transformer Turn Ratio TTR Tester with High Accuracy is high quality and efficient at a reasonable price that has high buyback rate! Our company continues to innovate, according to customer needs, market-oriented, and constantly improve the reliability, stability and practicability of our products. We expand our market, improve our facilities, strengthen internal management, form business characteristics, improve service quality so as to achieve the benign development of our company.

Hot Tags: HZTTR80A Three Phase Transformer Turn Ratio Tester, China, suppliers, manufacturers, price, for sale, 3 phase transformer turns ratio tester, digital transformer turns ratio tester, turns ratio test of a transformer, hzbb-10a three phase transformer turns ratio meter, hzbb10a, huazheng transformation ttr meter, transformer turn ratio test machine, turn ratio tester 250v, 3phase turn ratio tester, automatic variable ratio group tester, transformer ration test sets, ratio tester for power transformer, single phase turns ratio tester, 3 Phase Primary Current Injection Test Set, SF6 Gas Analyzer, 15kv insulation tester, battery conductance test, circuit breaker loop resistance tester, high current test set

[[ProKeywords]]

SPEC DATA

Send Inquiry

Send a Message