Hv Withstand Voltage Testers Oil Immersed AC DC Hipot Tester
Product Introduction
We are hoping to be able to produce more innovative and creative sf6 dew point tester, transformer test equipment list, tan delta test to improve the added value and quality of the products. The era has given us opportunities, but also brought challenges. Our staff are committed to providing customers with high-quality and professional sports flooring. We sincerely hope to win customer satisfaction with high-quality products and meticulous service concept, and constantly meet new challenges and create new brilliance. From product planning, design and R&D to mold manufacturing, production management, quality control, marketing and financial accounting, our company performs all corporate management standards. We are adhering to the pragmatic style of'innovation, truth-seeking, rigorous and efficient', customer demand-oriented, and dedicated to providing customers with satisfactory products and services.
HZG 50kV Dry Type AC DC Hipot Tester/ Dielectric Withstand Voltage Test Equipment
This series of test transformers utilizes advanced manufacturing equipment and incorporates new technologies, including epoxy vacuum casting for coil winding and a CD-type iron core. These innovations significantly reduce weight and volume while improving insulation strength and moisture resistance. In addition, leakage flux is effectively reduced, greatly enhancing the transformer's ability to withstand short-circuit current impacts during testing.

Technical Target
1. Impedance voltage | 4.5%-8% |
2. Idle load loss consumption | 0.2%-0.35% |
3. Allowable continuous operation time | 2 hours |
4. Interrupted operation time | continuous |



Major Technical Parameters
Model | Capacity | Input voltage | Output voltage | Output current | Output DC high voltage | Max. External dimension | Weight |
HZG-1.5/50 | 1.5 | 200 (400) | 50 | 30 | 70 | 250x180x370 | 13 |
HZG-3/50 | 3 | 60 | 330x270x600 | 30 | |||
HZG-5/50 | 5 | 100 | 400x330x700 | 48 | |||
HZG-6/50 | 6 | 120 | 300x310x680 | 46 | |||
HZG-10/50 | 10 | 200 | 430x370x750 | 73 | |||
HZG-20/50 | 20 | 400 | 470x370x750 | 85 | |||
HZG-30/50 | 30 | 600 | 500x380x780 | 120 | |||
HZG-5/100 | 5 | 100 | 50 | 140 | 430x370x1050 | 67 | |
HZG-10/100 | 10 | 100 | 470x370x1050 | 80 | |||
HZG-20/100 | 20 | 200 | 510x410x880 | 120 | |||
HZG-30/100 | 30 | 300 | 580x380x880 | 160 | |||
HZG-50/100 | 50 | 500 | 650x460x1010 | 230 |




Our pros are lessen prices, dynamic sales team, specialised QC, sturdy factories, top quality services and products for Hv Withstand Voltage Testers Oil Immersed AC DC Hipot Tester. With the technology as the core, develop and produce high-quality merchandise according to the diverse needs of the market. Our company practices the quality policy of running production in strict accordance with the quality management system.
Hot Tags: HZG 50kV 5kVA Dry Type AC DC Hipot Tester, China, suppliers, manufacturers, price, for sale, AC DC Hipot Test Set, 50 kv hipot tester, AC DC Hipot Test Set, AC DC Hipot Test Equipment, ac hipot 250kv 300kv, HIPOT 50KV 50mA, HZG AC Hipot Test Set, 5kva 100kv dry type ac hipot test set, dry type high voltage tester, DC and AC High Potential test sets, acdc hipot test kits, high voltage dry type testing transformer, 50KV AC 70KV DC 3KVA Hipot Tester, hi pot tester hzg, 300kv 30kva ac dc hipot tester, dielectric strength puncture tester, sf6 dew point tester, transformer capacity characteristic tester, astm d1816 astm d877 oil breakdown voltage testing, 3 phase relay test set, Battery Load Bank, lubricating oil testing machine