Tdc3100L 12kv Power Transformer Tan Delta and Capacitance Resistance Tester
tgδ: ±(reading×1%+0.00040)
Anti-interference index: Frequency conversion anti-interference, the above accuracy can still be achieved under 200% interference
Product Introduction
First class service and professional technicians make our company the pioneer in the same field and provide more high quality SF6 Gas Purity Test Set, winding resistance test set, 3 phase power quality analyzer price for our customers. We have a high-quality production technology team and complete sets of production equipment, sincere product quality awareness, flexible business mechanism. We expect to achieve win-win situation with the concept of equality, respect, sunshine and standardization. With superior products and complete specifications, our company insists on a high starting point, high standard, and high-quality work policy, and actively introduces technical personnel. We sincerely welcome friends from all walks of life to visit us. Our company's management personnel have many years of experience, can effectively combine the industry's advanced technology and products with its own characteristics to ensure that we can provide customers with high-quality products and affordable prices.
Product Introduction
The Transformer Dielectric Loss Tangent Delta Tester is an instrument specially designed for testing the capacity of standard distribution power transformers under low voltage and small current. Its main components include an LCD display, fuse box, grounding post, terminal block, etc. The Transformer Dielectric Loss Tangent Delta Tester is small in size and light in weight, with an integrated design that makes it easy to carry and operate in the field.

Features
HZ-2000H Transformer Dielectric Loss Tangent Delta Tester is sold well in the world market and worth recommendation for its excellent quality and reasonable price. Our tester can accurately measure the capacity of various distribution transformers with passive measurement, which is convenient and accurate. In addition, it comes with its own internal power supply and automatically generates three-phase high-power test power, which can measure no-load current, no-load loss, short-circuit voltage and short-circuit loss of various types of transformers.
Technical Index
Accuracy | Cx: ±(reading×1%+1pF) |
tgδ | ±(reading×1%+0.00040) |
Anti-interference index | Frequency conversion anti-interference, the above accuracy can still be achieved under 200% interference |
Electric capacity range | Internal high voltage:3pF~60000pF/10kV 60pF~1μF/0.5kV |
External high voltage | 3pF~1.5μF/10kV 60pF~30μF/0.5kV |
Resolution | Up to 0.001pF, 4 significant digits |
Range of tgδ | Unlimited, resolution 0.001%, automatic identification of three types of test samples: capacitance, inductance and resistance. |
Test current range | 10μA~5A |
Internal high voltage | Setting voltage range 0.5~10kV |
Maximum output current | 200mA |
Buck-boost mode | Voltage can be set at will. For example, 5123V. |
Test frequency | 40-70Hz single frequency can be set at will. For example, 48.7Hz. |
| 50±0.1Hz to 50±10Hz automatic double frequency conversion can be set at will. | |
| 60±0.1Hz to 60±10Hz automatic double frequency conversion can be set at will. | |
Frequency accuracy | ±0.01Hz |
High voltage applied externally | The maximum test current is 5A during positive connection, power frequency or frequency conversion 40-70Hz. Maximum test current when reverse wiring is 10kV/5A, power frequency or frequency conversion 40-70Hz |
CVT self-excited low voltage output | Output voltage 3~50V, output current 3~30A |
Measuring time | About 40s, related to the measuring method |
Input power | 180V~270VAC, 50Hz±1%, power supply from mains or generator |
Computer interface | Standard RS232 interface, U disk socket (automatic U disk storage data) |






Measurement Method and Principle
According to whether the tested product is grounded or not, there are two kinds of measurement methods, namely, the forward connection measurement method and the reverse connection measurement method. The principles of the two measurement methods are shown in figure 1:

At the 10kV side of the high-voltage power supply, the high-voltage power supply is divided into two channels, and the first channel feeds the standard capacitor CN inside the machine. The dielectric loss of this capacitor is very small, which can be considered as zero, i.e. pure capacitive current. This current ICN can be used as the capacitive current reference. On the Cx test side, the test current Icx is collected into the machine through the sampling resistance R. The Icx can be decomposed into horizontal and vertical components, as shown in figure 2. tgδ value can be obtained by calculating the ratio of the horizontal and vertical components.
In FIG. 1 (a), Cx is the ungrounded sample, and the sample current Icx enters the sampling resistance R from the sample end to obtain the full current value. In FIG. 1 (b), Cx is the grounding sample, the Cx end of the machine is directly grounded, and the current Icx obtains the full current value from the high-voltage end of the sample to the sampling resistance of the machine.





Using a total scientific good quality management process, superior high quality and excellent faith, we get great name and occupied this field for Tdc3100L 12kv Power Transformer Tan Delta and Capacitance Resistance Tester. We have established and implemented a quality management system to give quality product resources directly to our customers. We are permanently aware that our innovative ideas and products come from our employees, who are our most important asset.
Hot Tags: HZ-2000H Transformer Dielectric Loss Tangent Delta Tester, China, suppliers, manufacturers, price, for sale, transformer tangent delta test, anti-interference dielectric loss tester, tangent delta test set, dielectric loss tangent test, tangente delta meter, transformer dielectric loss instrument, 10KV Insulation Power Factor Tester, HZ-2000H, Anti interference dielectric loss tester, tg delta test, tangen delta tester, 12 kv tan delta tester, tangent delta tester for motor, lubricating oil testing machine, transformer no load losses test, transformer oil filtering machine, 2000A Primary Current Injection Test Set, underground Cable Fault Locator, digital tan delta tester
[[ProKeywords]]SPEC DATA