+86-312-6775656
Automatic Hig Voltage High Current Cable Tan Delta and Capacitance Dielectric Loss & Dissipation Factor Tester 10A 1000kv Cable C&Df Tester

Automatic Hig Voltage High Current Cable Tan Delta and Capacitance Dielectric Loss & Dissipation Factor Tester 10A 1000kv Cable C&Df Tester

1) Please make grounding connection for sample object, HV transformer and main control box first
2) Please discharge the sample object if the sample object is a capacitive equipment.
Send Inquiry
Product Details of Automatic Hig Voltage High Current Cable Tan Delta and Capacitance Dielectric Loss & Dissipation Factor Tester 10A 1000kv Cable C&Df Tester

Product Introduction

Our Single Phase Relay Tester, Insulation Resistance Tester 10kv, oil flash point testing machine because of its superior quality and advanced technology to achieve the best-selling domestic and foreign markets. We focus on technology research and development, and continue to innovate with our advanced production equipment. Our company has advanced production equipment and various production and testing equipment. Our company will serve customers and the society with the corporate culture of honesty, enthusiasm, upward mobility and hard work.

HZQ AC Hipot SF6 Gas Inflated Type Power Frequency Testing Transformer

SF6 Inflated Testing Transformer

Technical parameters of HZQ series alternating current test transformers

Model

Capacity (KVA)

High Frequency Voltage
Output Voltage
(KV)

High Frequency
Voltage
Output
Current (mA)

Low Frequency Voltage input

V

A

HZQ-1.5

1.5

50

30

200

7.5

HZQ -3

3

50

60

200

15

HZQ -5

5

50

100

200

25

HZQ -10

10

50

200

230/400

50/26

HZQ -20

20

50

400

380

53

HZQ-30

30

50

600

380

79

HZQ -40

40

50

800

380

105

HZQ -50

50

50

1000

380

132

HZQ-5

5

100

50

200

25

HZQ -10

10

100

100

200/380

50/26

HZQ -20

20

100

200

380

53

HZQ -30

30

100

300

380

79

HZQ-40

40

10

400

380

105

HZQ-50

50

100

500

380

132

HZQ-100

100

100

100

500

263

HZQ-150

150

100

1500

500

300

HZQ-200

200

100

2000

500

400

HZQ-250

250

100

2500

380

500

HZQ-20

20

150

133

380

53

HZQ-30

30

150

200

380

79

HZQ-50

50

150

333

380

132

HZQ-100

100

150

666

500

263

HZQ-150

150

150

1000

500

300

HZQ-200

200

150

1333

500

400

HZQ-250

250

150

1666

380

500

HZQ-30

30

200

150

380

79

HZQ-50

50

200

250

380

132

HZQ-100

100

200

500

380

263

HZQ-150

150

200

750

500

300

HZQ-200

200

200

1000

500

400

HZQ-250

250

200

1250

500

500

HZQ-30

30

250

120

380

79

HZQ-50

50

250

200

380

132

HZQ-100

100

250

400

380

263

HZQ-150

150

250

600

500

300

HZQ-200

200

250

800

500

400

HZQ-250

250

250

1000

500

500

The operation of the insulation test with HIPOT tester is as follows:

1) Please make grounding connection for sample object, HV transformer and main control box first

2) Please discharge the sample object if the sample object is a capacitive equipment.

3) Please make connection for tester and sample object according to figure 3.

4) Please make power connection for main control box.

5) Confirm the high voltage value in withstand.

6) Setting the protection value of current by the pointer on the over current protection relay panel.

7) Adjust the regulator to zero position and then press down the close button on the panel the tester with enable the high voltage output unit.

8) If the regulator is not at zero position when you press down the close button the high voltage output unit would not be enabled. 

There is a zero position indicator light on the panel of the main control box.

9) Adjust the high voltage output to the withstand test value step by step. Read the high voltage value and LV current from meters at the same time.

10) Start the timer by the timer switcher on the main control box panel when the high voltage has.

11) If the current over the value set on the panel of the over current relay the tester would cut off the power supply of HV transformer immediately. It is said the test result is failure.

12) If the timer display value reach the set value the tester would have a sound alarm to inform operator that the withstand time is ok. If the tester has not start the over current protection unit before sound alarm it is said the test result is ok.

13) Open the power supply of HV transformer by press down the "open" button on the panel of the main control box when test is end.

14) Please discharge the high voltage circuit of sample equipment before remove off the cable connection of high voltage circuit.

Please do not start the test if some part of the tester had been destroyed.

SF6 Inflated Testing Transformer

SF6 Inflated Testing Transformer

SF6 Inflated Testing Transformer

SF6 Inflated Testing Transformer

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

image014

image016

Request for quote_

Our company will have the courage to innovate the pioneering spirit and rigorous scientific attitude into high quality and low price Automatic Hig Voltage High Current Cable Tan Delta and Capacitance Dielectric Loss & Dissipation Factor Tester 10A 1000kv Cable C&Df Tester and standard and thoughtful service. We will be committed to providing customers with the best service through new media platforms such as the global Internet and wireless networks, with unique and creative planning, precise communication channels and efficient marketing execution. Our customers are always satisfied with our reliable quality, customer-oriented services and competitive prices.

Hot Tags: HZQ SF6 Inflated Type Electrical Testing Transformer, China, suppliers, manufacturers, price, for sale, Inflated Type High Potential Testing Transformer, Inflatable High Voltage Testing Transformer, AC DC Testing Transformer, SF6 Gas Insulated Inflatable Testing Transformer, HZQ, Cable testing transformer 3 kva, underground cable fault detector, circuit breaker test unit, hipot test transformer, 11kv discharge rod, DC System Ground Fault Locator, gas chromatography gas auto sampler

[[ProKeywords]]

SPEC DATA

Send Inquiry

Send a Message