+86-312-6775656
GDBR-P Transformer Power Analyzer/Transformer Capacity Tester/Transformer Impedance Voltage Tester

GDBR-P Transformer Power Analyzer/Transformer Capacity Tester/Transformer Impedance Voltage Tester

This test equipment comes with a high-efficiency rechargeable battery, which can work without an external power supply. It can continuously measure 500 units after a charge.
Send Inquiry
Product Details of GDBR-P Transformer Power Analyzer/Transformer Capacity Tester/Transformer Impedance Voltage Tester

Product Introduction

After years of hard work, our company has accumulated rich experience in the automatic interfacial tensiometer, dissolved gas content analyzer, Transformer Oil Purifier industry, and we look forward to cooperating with you sincerely. Welcome to negotiate business. Developed transportation, communication, information, and network closely connect the company with the world and provide a good opportunity for the further development of the company. We independently develop diversified product structures.

HZ-6300C Transformer Capacity And Loss Characteristic Tester

Summary

This transformer capacity testing instrument is equipped with a high-efficiency rechargeable battery, enabling operation without an external power supply. It can perform up to 500 consecutive measurements on a single charge.
Meanwhile, it internally generates a three-phase standard sine-wave signal through digital synthesis (rather than simple inverter-based AC output), ensuring accurate test data under non-rated conditions for the following test items. Its power amplifier module provides a high-precision three-phase AC test source. When measuring transformer capacity and short-circuit loss, no auxiliary equipment-such as a three-phase test power supply, voltage regulator, or step-up transformer-is required.

HZ-6300C Transformer Capacity Characteristic Tester

Technical Data

The output range of built-in battery

Voltage

0~10V

Current

0~10A

The output range of test battery

Voltage

0~750V

Current

0~100A

Precision

Voltage, current

±0.2%

Power

±0.5%(CosΦ>0.1), ±1.0%(0.02<CosΦ<0.1)

Volume

32×25×12

transformer capacity test set

Note

1. The connecting method of testing line should operate according to instruction, otherwise it will affect the result

2. The wiring should be proceeded when the testing line has grounded in order to electric shock of induced voltage.

3. Please ensure the voltage ,current under the testing range. It need to connect with CT PT to expand the range, or testing result will not right.

4. When instrument do capacity test, active load test, load test,

Please ensure the short circuit of the no-pressure side, otherwise it will affect the result.

5. When doing the load test, if there is the power casing of HV LV side(Eg: CT), Please ensure short circuit of secondary winding of CT.

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

image007

image009

Request for quote_

We are committed to providing the best solutions for the global GDBR-P Transformer Power Analyzer/Transformer Capacity Tester/Transformer Impedance Voltage Tester field. We strictly control each production process, and all products have undergone multiple quality inspections. We will always take "Customer Satisfaction" as our tenet, strive for excellence, keep pace with the times, keep up with the times, and serve our customers sincerely. As a responsible company, we always pay attention to the health of our employees.

Hot Tags: HZ-6300C Transformer Capacity and Loss Characteristic Tester, China, suppliers, manufacturers, price, for sale, Transformer Capacity and Load Tester, Transformer Capacity Test Equipment, transformer capacity characteristic test instrument, transformer capacity and characteristic test system, hz6300c, hz-6300c, transformer capacity loss test machine, transformer capacity loss parameters tester, Transformer Capacity And No-load Tester, battery discharge machine, primary current injection test set manual, transformer turns ratio test, automatic lubricant dropping point tester, cable fault finder, astm d1401 demulsibility test

[[ProKeywords]]

SPEC DATA

Send Inquiry

Send a Message