+86-312-6775656
HZDL-200III 200A Three Phase Primary Current Injection Test Set

HZDL-200III 200A Three Phase Primary Current Injection Test Set

HZDL-200III High Current Generator Features Using beautiful and elegant PVC panel Display the primary current directly, which is convenient for test observation and recording. High measurement accuracy: 0.5 class High power, small size and strong load capacity Small size and light weight, the...
Product Details ofHZDL-200III 200A Three Phase Primary Current Injection Test Set

Huazheng Electric Manufacturing (Baoding) Co., Ltd. is one of the leading manufacturers and suppliers of hzdl-200iii 200a three phase primary current injection test set in China. Please feel free to buy high quality equipment for sale here from our factory. Good service and reasonable price are available.

 

HZDL-200III High Current Generator

 

Technical characteristics

Item Specification
Input Voltage AC 380/220 V, 100 Hz, three-phase four-wire
Rated Power 1 kVA (1 × 3)
Output Current AC 0–200 A × 3, stepless adjustable; equipped with panel digital ammeter
Output Voltage >3 V
Output Waveform Standard sine wave with low burrs, fully compliant with power industry standards; ripple coefficient < 0.3%

 

Operation

(1) After the wiring is completed, check it again to see if there is any wiring error and whether the connectors are in good contact.

(2) During the test, if there is any abnormal phenomenon such as ignition and no display when starting up, immediately turn off the power and recheck the wiring.

(3) During the actual wiring, the current output terminal should form a loop, otherwise the instrument will not output current.

(4) The current riser is supplied with output wires. External copper wires should be selected at a rating of 50 A per mm². (The standard configuration includes two 3-meter test leads.)

(5) The equipment's capacity is designed for short-time operation of 10 minutes. For batch testing, the working time should be less than 10 minutes, and the next test should be performed after a 10-minute waiting period. If temperature rise testing (30 minutes to 24 hours) is required, the equipment must be prepared for long-term continuous operation.

 

Contact Information

Contact: Sunny Shen

Department: Sales Manager

Telephone

+86-312-6775656

Mob/Whatsapp

0086-13731499206

Email

sales01@electric-hz.com

Skype

sunnyshen1103

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

image014

image016

Request for quote_

Hot Tags: hzdl-200iii 200a three phase primary current injection test set, China, suppliers, manufacturers, price, for sale, Primary Current Injection Test Equipment, 1000A Primary Current Injection Test Set Price, 2000A Primary Current Injection Test Set, primary current injection test, Primary Current Injection Test Instrument, primary current injection test set manual

Send Inquiry

(0/10)

clearall