HZCR-5000 Smart Multi-function Power Quality Analyser
Huazheng Electric Manufacturing (Baoding) Co., Ltd. is one of the leading manufacturers and suppliers of hzcr-5000 smart multi-function power quality analyser in China. Please feel free to buy high quality equipment for sale here from our factory. Good service and reasonable price are available.
HZCR-5000 Smart Multi-function Power Quality Analyser
A three-phase power quality analyzer is a device used to analyze and monitor power quality in three-phase power systems. It measures parameters such as voltage, current, power factor, harmonics, and voltage dips. The instrument typically consists of a display, data storage, measurement sensors, and control devices.

General Specifications
| Parameter | Specification |
|---|---|
| Model | HZCR-5000 |
| Processor | DSP (>200MHz) + ARM dual-core |
| ADC | 2 × ADI AD7655, 16-bit, 4-channel synchronous, up to 1 MSPS |
| Voltage Channels | 4U / 4I (4 voltage + 4 current) |
| Phase-to-Neutral Voltage | 1.0V – 1,000V |
| Phase-to-Phase Voltage | 1.0V – 2,000V |
| Current Range | 10mA – 6,000A (via interchangeable clamps) |
| Frequency Range | 40Hz – 70Hz |
| Harmonic Analysis | Orders 1–50, voltage + current + apparent power |
| Voltage Accuracy (RMS) | ±(0.5% + 5dgt) |
| Current Accuracy (RMS) | ±(0.5% + 5dgt) |
| Active Power Accuracy | ±(1% + 3dgt) @ cosφ ≥ 0.8; ±(1.5% + 10dgt) @ cosφ 0.2–0.8 |
| Frequency Accuracy | ±0.03Hz |
| Display | 5.6-inch colour LCD, 640×480 pixels |
| Transient Records | 150 sets (4-cycle waveform per event) |
| Inrush Current Capture | 100 seconds continuous |
| Trend Recording | 300 days (20 parameters at 5s interval); 2GB SD card |
| Alarm Log | 12,800 entries; 40 configurable groups; 123 monitorable parameters |
| Screen Snapshots | 60 images |
| Network Connections | Single-phase, split-phase, 3-wire / 4-wire / 5-wire three-phase |
| Safety Standard | IEC 61010 CAT.III 1000V / CAT.IV 600V; IEC61326; Pollution degree 2 |
| Battery | 9.6V Li-ion, 4,500 mAh, 8 hours continuous; charges via included mains adapter (AC 100–240V) |
| Communication | USB (to PC via included software) |
| Operating Temperature | –10°C to 40°C |
| Humidity | < 80% RH |
| Dimensions | 240 × 170 × 68 mm |
| Weight | 1.6 kg (with battery) |
| Languages | Chinese / English |

The direction of the end of the current clamp with the same name is as follows:
The current clamp is marked with an arrow, and the direction of the arrow is the input side, which is the input end of the same direction as the current, that is, the end with the same name.
The S-008 current clamp is marked with an arrow, and the direction of the arrow is the input side, which is the same-direction input end of the current, that is, the end with the same name.
S-070, S-105, and S150 current clamps are marked with red arrows, and the direction of the arrow is the input side, which is the input end of the same direction as the current, that is, the end with the same name.
The S-200JF flexible coil current sensor is marked with a black arrow, and the direction of the arrow is the input side, which is the input end of the same direction as the current, that is, the end with the same name.
CE Certificate

How do I select the right current sensor and verify correct connection polarity?
Sensor selection: Match the expected maximum current to the sensor range - always use the smallest sensor whose range exceeds the maximum current. Using a 1,000A clamp on a 5A circuit gives poor resolution; using a 10A clamp on a 50A circuit will overrange the input.
Polarity identification (critical - reversed polarity causes incorrect power sign and phase angle):
10A clamp: the side with the red dot is the current non-inverting input (→ toward the load)
100A / 1,000A clamp: the side without screws is the current non-inverting input (→ toward the load)
6,000A Rogowski coil: the arrow icon (lock logo side) marks the current direction input
Quick polarity check: after connecting, display the phasor diagram. In a normal inductive load with correct connections, the current vector for each phase should lag its corresponding voltage vector by a small angle (0°–90°). If a current vector leads voltage or points in the opposite direction from the other phases, that CT is reversed.



Hot Tags: HZCR-5000 Smart Multi-function Power Quality Analyser, China, suppliers, manufacturers, price, for sale, power quality tester, 3 phase power quality analyzer price, 6000a measure current power quality analyzer, 3phase power quality analyzer, power quality analyzer with data logger, pqa analyzer