+86-312-6775656
Huazheng HZAWA5661 Class 1 Sound Level Meter

Huazheng HZAWA5661 Class 1 Sound Level Meter

Huazheng HZAWA5661 Class 1 Sound Level Meter General Introduction Model HZAWA5661 Sound level meter is digital and multifunction sound level meter with modular design. Its performance accords with standard IEC 61672: 2002 Class 1, belongs to group X sound level meter for specifying the emission, and susceptibility...
Send Inquiry
Product Details ofHuazheng HZAWA5661 Class 1 Sound Level Meter

 

Huazheng HZAWA5661 Class 1 Sound Level Meter

 

General Introduction

The HZAWA5661 sound level meter is a digital, multifunctional sound level meter with a modular design. Its performance complies with IEC 61672:2002 Class 1, and it belongs to Group X sound level meters for specifying emission and susceptibility to radio frequency fields.

The meter incorporates advanced digital detection technology, featuring automatic range conversion, reliable and stable performance, and a wide linear operating range. The housing is made of ABS engineering plastic, offering an attractive appearance, light weight, and easy portability. Power consumption is low. The RS-232 digital output interface enables remote computer control and telemetry. Additionally, multiple meters can be networked for computer-controlled monitoring and measurement.

It is widely used for measuring noise generated by various machines, vehicles, boats, and electrical equipment, as well as environmental and industrial noise, including applications in labor protection and industrial hygiene.

The HZAWA5661 sound level meter is available in multiple models. They share the same structure and operating principle, differing only in the microphone type and software authorization.

 

Specification

(1)Microphone: Φ12.7mm (1/2'') pre-polarization condenser microphone. Sensitivity: 30mV/Pa. See the appendix A.

Users can also equip the instrument with other types of microphones, enabling measurement of very low or very high noise levels.

Types of microphones

Type

External

diameter(mm)

Sensitivity (mV/Pa)

Frequency Range (Hz)

AWA14425

Φ12.7

30

10~16000

AWA14423

Φ12.7

40

10~20000

AWA14411

Φ23.77

80

10~16000

AWA14431

Φ6.35

4

10~20000

(2)Dynamic range

Type

A- Weighting Self-generated Noise

A-

Weighting

Self-generated Noise

Z-

Weighting

Meas. Upper Range

AWA14425

<20dB(A)

<25dB(C)

<30dB

140dB

AWA14423

<18dB(A)

<23dB(C)

<28dB

138dB

AWA14411

<10dB(A)

<15dB(C)

<20dB

132dB

AWA14431

<40dB(A)

<45dB(C)

<50dB

160dB

(3)Frequency Range:10Hz~16kHz, while use the AWA14423 or AWA14431 Microphone, the Frequency Weighting can get to10Hz~20kHz

(4)Frequency Weighting: A, C, Z. The response in free field see the appendix B.

(5)Time Weighting: F, S, I, Peak

(6)Detectors Characteristics: the true effective value, digital detection, peak factor≥10.

(7)Accuracy: IEC 61672:2002 Class 1

(8)Range control: high and low two gears, high and low two gears, each gear 20 dB attenuation, reference level range linear range ≥95 dB.

(9)Display: 128×64 OLED

(10)Output interface: AC, DC, RS-232, USB interface

(11)Calibration: use Model AWA6221A sound level calibrator conformed to specifications of IEC 60942 for Class 1 for the performance class.

(12) Power: battery 4×LR 6, which can work at least 16 hours successively. External power: 5V~9V, 0.2A

(13) Dim. (H×W×D) mm: 310 mm×72 mm×32 mm

(14)Weight (kg): 0.4

(15)Operation environment:

Air temperature: -15℃~+50 ℃

Relative humidity: 10 %~90 %

Air pressure: 65 kPa~108 kPa

(16)Measurement range:

Type

Measurement range(dB)

Peak

factor Ref.10 dB

Peak

measurement range(dB)

AWA14425

45~140

45~123

70~143

27~120

27~103

50~123

AWA14423

43~138

43~121

70~141

25~80

25~101

50~121

AWA14411

35~132

35~115

60~135

15~112

15~95

40~115

AWA14431

65~160

65~143

90~163

45~140

45~123

70~143

Above range is the value in the factory, it may have changed when the user tuned the calibration value or replaced the microphone. The lower limit is determined by the background noise plus 8dB.

(17)Different configuration:

Different configuration contrast table

Items

1

2

3

Weighting

A, C, Z,B

A, C, Z,B

A, C, Z,B

Time Weighting

F, S, I,Peak

F, S, I, Peak

F, S, I, Peak

Outputs

AC,DC,RS232

AC,DC,RS232

AC,DC,RS232

Integrating function

No

Yes

Yes

Statistical Analysis

No

No

Yes

Calendar clock

No

No

Yes

Main Parameters of Measurement

Lp, Lpeak, Lmax

Lp, Lpeak, Lmax, Lmin, SEL, E

LFp, LSp, LIp,

Leq,t, Lpeak, Leq,T, LFmax, LFmin, LSmax, LSmin, LImax, LImin, SEL, Lex8h, LAVG, TWA, DOSE, Ln1, Ln2, Ln3, Ln4, Ln5,

SD,Ts, Tm, Volt, E.

USB port

No

No

Yes

Data storage

No

No

Yes

Note1: The n1 to n5 in Ln1-Ln5 can be chosen from 1 to 99.

Note2: The 5636-3 can choose logging and recording function. Logging the curve of the time-weighting sound pressure level and short-time equivalent sound pressure level changing with the time; Recording the sound WAV file with sampling frequency 48kHz﹑ 48kHz and 12kHz.

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

image014

image016

Request for quote_

Hot Tags: Huazheng HZAWA5661 Class 1 Sound Level Meter, China, suppliers, manufacturers, price, for sale, dc ground fault locator, ultrasonic flaw detector equipments, huazheng electric hz9110, refilling device sf6, ct test bench, multimeter calibrator

Send Inquiry

(0/10)

clearall