HZRC1810 35kV AC/DC Voltage Tester
Introduction
HZRC1810 AC/DC Voltage Detector is applied for measuring the voltage to ground and electricity testing & alarm of the power high and low voltage lines and railway overhead lines. The voltage measurement range up to 35kV. The instrument adopts the telescopic rod structure with contraction length 1600mm and extend length 5000mm. When the power transmission line is shut down for maintenance, due to the capacitance effect, the adjacent operating lines will generate induced voltage, which seriously threatens the safety of the inspection and testing instruments and maintenance operators. This instrument can quickly measure the voltage of the transmission line during operation or the induced voltage during maintenance to protect the safety of equipment and operators.
HZRC1810 AC/DC Voltage Detector has the audible and visual prompt function. When the line voltage is larger than the safe voltage value, the audible and visual alarm will sound to remind the operator to pay attention to safety. The instrument has automatic shutdown function, and the instrument will automatically shut down without any operation after starting up 10 minutes. The instrument is easy to carry and simple to operate, providing a safe, practical and convenient new type of power measuring instrument for power inspectors.

| Functions | AC, DC voltage to ground measurement |
| Power Supply | Detector: DC 9V Alkaline dry battery (LR6 1.5VX6PCS) |
| Voltage Measurement Range | AC/DC 30V~35kV |
| Voltage Measurement Accuracy | ±2%±8dgt |
| Voltage Resolution | 1V |
| Frequency Measurement Range | 50Hz/60Hz |
| Input Resistance | Approx. 150MΩ |
| Test Current | <0.4mA@35kV |
| LCD Size | 47mmX28.5mm |
| Alarm Indication | When the voltage <36V during the test, the green indicator light is on; When the voltage ≥36V during the test, the red indicator light is on and the buzzer alarm function is triggered |
| Automatic Shutdown | The detector will automatic shutdown after starting up 10minutes without any operation |
| Low Battery Voltage Indication | When the detector battery voltage is lower than 7.2V±0.1V, low battery voltage symbol "🔋" will display and remind to replace battery. |
| Instrument Weight | Total weight approx. 4.5kg(include accessories) |
| Instrument Size | 1680mmX102mmX83mm; |
| Insulation Rod Length | Contraction state 1600mm, stretched state 5000mm |
| Insulation Test | The insulation rod stretched to both ends: AC 220 kV / rms Between exposed metal and plastic housing: AC3700V / ms |
| External Interference | No extremely strong electromagnetic fields |
| Working Temperature | -10℃~40℃; Below 80%RH |
| Storage Temperature | -10℃~60℃; Below 70%RH |