Product description:
The AAS6000 series atomic absorption spectrophotometer is a single-beam instrument that is used for function control and data processing by a computer and an internal CPU chip. It is used to determine the content of constant, trace, trace metal elements and semi-metal elements in various substances.
Atomic absorption spectrometer meet with the international standard ASTM D5863,it is a measurement method that utilizes the phenomenon of ground state atoms absorbing characteristic wavelengths
Atoms are usually in the ground state. For each element, the energy required for the transition from the ground state of the atom to the excited state is certain. This specific energy is called the characteristic line. In atomic absorption spectroscopy, a hollow cathode lamp is used as a light source to emit a characteristic wavelength of an element. After passing through the element's atomic vapor, the atomic vapor absorbs the characteristic wavelength light, and the element atomic concentration is calculated according to the degree of light absorption.
The instrument provides three reading modes of continuous, holding and peak height for the determination of absorbance, concentration and emission intensity. It has atomic absorption, background absorption, background absorption and four signal modes. The reading time is optional from 0.5 seconds to 99 seconds. The instrument has eight computer-controllable hollow cathode lamp holders. The various working conditions of the instrument are: lamp number, lamp current, negative high voltage, working wavelength, slit, burner position, ignition/quenching, combustion ratio adjustment and other conditions All settings can be controlled by software. It has functions such as automatic gain/automatic zero adjustment, background correction, automatic energy balance, automatic peak search/wavelength scanning, and automatic peak search according to the peak search method. All readings, measurement results, calibration curves and operating conditions can be stored or printed by the printer.
Application areas:
Geology, minerals, metallurgical industry analysis, steel analysis, non-ferrous metal analysis
Environmental analysis, air analysis, water quality analysis, soil analysis
Analysis of petrochemical and light industrial products Analysis of crude oil and its processed products, analysis of chemical light industrial products
Food analysis, biomedicine, health product analysis and pollution-free agricultural products, feed.


Main part:
Hollow cathode lamp
Flame control system
Monochromator
Circuit control system
Power requirements:
Single-phase 220V±10% 10A Yikuai (Navigate Yihuan)
One switchboard (220V, 10A), the device is within 10m from the switchboard, and is equipped with a ground wire.
Two wiring sockets (220V, 10A).
technical parameter:
Model: AAS6000
Spectrometer system: total reflection type single beam CT type optical path
Monochromator focal length: 350mm
Grating blaze wavelength: 230nm
Grating line number: 1800g/mm
Wavelength range: 190nm-900nm
Wavelength accuracy: soil 0.03nm
Wavelength repeatability: ±0.1 nm
Spectral bandwidth: 0. 1/0. 2/0. 4/0. 7/1. 4 nm
Noise: 0.005 Abs (static); 0.006 Abs (dynamic)
Baseline drift: 0.005Abs/0.5 h
Deduction background method: change the light
Number of lights: 8
Number of preheating lamps: W8 can be controlled by software
Pneumatic safety protection: air pressure monitoring, B-pressure monitoring, flow feedback Atomizer: flame atomizer
Degree of automation: lamp/slit/wavelength/gas path/ignition/burner/protection/C 2 monitoring