120kV 5mA DC High Voltage Hipot Tester

Jun 07, 2023

Application range

The DC high voltage tester is mainly suitable for the power department of the power department, industrial and mining, metallurgy, steel and other enterprises to conduct DC withstand voltage tests or DC leakage current tests on zinc oxide arresters, power cables, transformers, circuit breakers, generators and other high-voltage electrical equipment.

Boost mode: manual boost.

dc hipot tester

Technical features

ZGF-B DC high voltage generator. Using AIPWM technology, the inaccurate linearity of PWM technology has been adjusted, so that the accuracy of the instrument has been greatly improved. And the use of AI technology to set overvoltage protection and overcurrent protection on the screen replaces the problems that the digital dial switch can only set the voltage value, but cannot set the current value and voltage drift. 0.75UDC1mA function button, convenient for zinc oxide arrester test, accuracy ≤ 1%. Added the timing function under arbitrary voltage and current, and the functions of total time T1 and segment timing T2. The instrument has added perpetual calendar and time functions.

·The chassis adopts a portable chassis, which is easy to carry.

·Using AIPWM technology, the inaccurate linearity of PWM has been adjusted, and the precision has been greatly improved. Ripple factor ≤0.5%.

· AI zinc oxide arrester and oil-immersed transformer measurement function. The experimental report can be saved directly, with an accuracy of ≤0.5%. Keep manual 0.75UDC1mA.

·The use of AI technology to set overvoltage protection and overcurrent protection replaces the problem that the digital dial switch can only set the voltage value, but cannot set the current value and voltage drift. Error≤1%

Full-scale smooth voltage regulation, voltage regulation accuracy ≤ 1%, stability ≤ 1%, voltage and current error ≤ 1.0% ± 1 digit

·With total time T1 and split timing T2, and timing function under any voltage and current.

·The perpetual calendar and time functions are added to the instrument.

Main technical performance and specifications and working methods:

 

Specification

Parameters

 

60/2

120/2/5

200/2/5

300/2

output voltage

(kV)

60

120

200

300

Output current(mA)

2

2/5

2/5

2

Output Power (W)

120

240/600

400/1000

600

recharging current (mA)

2

3/4.5

3/5

3

Control box weight(kg)

11.6

13

13.1

13.1

Pressure doubler cylinder weight(kg)

2.3

3.2

8.0

10

Pressure doubler specifications(mm)

Ф90

380

Ф1100

470

Ф110

910

Ф110

1500

voltage measurement error

1.0%±1reading

current measurement error

1.0%±1reading

Overvoltage setting error

AI technology sets overvoltage protection and overcurrent protection. Error≤1.0%

0.75switching error

High-precision 0.75UDC-1mA one-touch button (accuracy ≤ 0.5%)

Most suitable for zinc oxide arrester test

Ripple coefficient

≤0.5%

Working Mode

Intermittent use: rated load 30 minutes

1.1 times rated voltage use: 10 minutes

working environment

Temperature: -10℃~+40℃

Relative humidity: no more than 85% when the room temperature is 25°C (no condensation)

Altitude: below 1500 meters

with capacitive load

The capacitance of the tested product is unlimited

Structural features

Electrical insulation pressure doubler

Air insulation, no leakage concerns