+86-312-6775656
HZ-1041 Three Phase Electrical Energy Meter Test Bench

HZ-1041 Three Phase Electrical Energy Meter Test Bench

HZ-1041 Three Phase Electrical Energy Meter Test Bench Basic Functions Of The Platform Various three-phase watt-hour meters (electronic, inductive and four-quadrant reactive watt-hour meters) with the same specification and different constants can be verified at the same time. You can choose...
Send Inquiry
Product Details ofHZ-1041 Three Phase Electrical Energy Meter Test Bench

Huazheng Electric Manufacturing (Baoding) Co., Ltd. is one of the leading manufacturers and suppliers of hz-1041 three phase electrical energy meter test bench in China. Please feel free to buy high quality equipment for sale here from our factory. Good service and reasonable price are available.

 

HZ-1041 Three Phase Electrical Energy Meter Test Bench

 

Basic Functions Of HZ-1041 Three Phase Electrical Energy Meter Test Bench

Various three-phase watt-hour meters (electronic, inductive and four-quadrant reactive watt-hour meters) with the same specification and different constants can be verified at the same time.

You can choose to operate with small keyboard or PC. The functions of each key operated by the small keyboard are clearly marked, with LCD liquid crystal display, Chinese prompts, intuitive and convenient operation. The PC control software has clear layers, beautiful interface, flexible and convenient to use. Equipped with Chinese test software under WINDOWS98/2000/XP, it can control the device to realize the automatic test of various electric energy meters.

It has the function of barcode scanning and entering table number.

According to the requirements of the regulations, automatic verification is carried out for the verification items such as creep, starting, basic error, and standard deviation. It is also possible to freely select points and determine the verification scheme. The verification scheme can be intelligently configured according to the regulations or manually set.

It can measure the amount of change caused by influences such as voltage, frequency, reverse phase sequence, voltage unbalance, and harmonic influence.

The test results can be saved in the database to realize data statistics, classification, query and management. It can also be connected to the customer's management system to upload test data.

Calibration of electric energy constant, and can carry out reading of common meter and multi-function meter.

Supports report customization, supports custom data export, allows fields to be named by themselves, and can be connected to the report designer to design reports.

Output voltage, current overload with automatic protection, sound and light alarm function.

 

Output voltage Range

3×57.7V/100V/230V/380V

Output voltage Adjustment fineness

better than 0.01%

Output voltage stability

≤0.05%/3 minutes

Output voltage distortion

≤0.5%

Output voltage capacity

20VA/epitope

Harmonic output

2~21 harmonics, content ≤40 % ;

Electrical Energy Meter Test Bench

Multi Function Test Items

GPS time synchronization: You can use the 485 broadcast command to provide time, and you can also use the 485 setting command to write the time.

Daily timing error test: It can simultaneously measure the accuracy of second pulse output by multi-function electric energy meters with multiple gauges, and can optionally automatically convert it to daily timing error for display.

Time-period switching error test: For multi-function electric energy meters that output time-period switching signals, the time-period switching error test can be performed, and for multi-function electric energy meters without output switching signals, qualitative time-period switching results can be given according to communication, and also Time synchronization and timing operations can be performed on the multi-function electric energy meter through the communication interface.

485 port communication function: Through the 485 communication port, it is possible to perform operations such as memory power check and parameter setting on the multi-function electric energy meter with a communication port.

Demand indication value error test: The device can use the standard electric energy meter method or standard power method to test the demand indication value error of the multi-function electric energy meter. The standard electric energy method is used to test the electric energy meter with the output demand period signal, and the standard power method is used to test the electric energy meter without the quantity periodic output signal. The average power calculation method during the test can be the slip method or the average power method.

Demand periodic error test: When the standard power meter method is used to measure the demand indication error, the pulses sent by the standard crystal oscillator within two (interval type) or multiple (slip type) periodic signal intervals of the tested meter are counted by the error meter When the standard electric energy meter method is used to measure the error of the demand indication value, it is timed by the internal timer of the error meter.

Combination error test of electric energy meter: change the clock in the meter under test through the RS485 interface, complete the operation of each tariff segment in a relatively short period of time, and calculate the combined error by comparing the total meter and the change amount of each tariff meter . The mechanical scale allows manual input of start and end indications, and can compare the difference between the mechanical scale and the memory.

 

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

image014

image016

Request for quote_

Hot Tags: hz-1041 three phase electrical energy meter test bench, China, suppliers, manufacturers, price, for sale, energy meter test bench, electric meter calibration machine

Send Inquiry

(0/10)

clearall