+86-312-6775656
HZ-3310B 10A Three Phase Transformer Winding DC Resistance Tester

HZ-3310B 10A Three Phase Transformer Winding DC Resistance Tester

HZ-3310B 10A Three Phase Transformer Winding DC Resistance Tester Tech Data Output current: Three-phase test: 5A+5A; 1A+1A; 200mA+200mA; 20mA+20mA; Single-phase test: 10A; 5A; 1A; 200mA; 20mA; Measurement range: Three-phase test: 5A+5A: 2mΩ~1.2Ω; 1A+1A: 10mΩ~6Ω; 200mA+200mA: 100mΩ~30Ω;...
Product Details ofHZ-3310B 10A Three Phase Transformer Winding DC Resistance Tester

 

HZ-3310B 10A Three Phase Transformer Winding DC Resistance Tester

 

HZ-3310B 3-phase winding resistance measuring instrument.To meet the requirements for rapid measurement of transformer DC resistance, our company has developed a large‑scale power transformer DC resistance rapid tester that integrates three‑phase simultaneous test function, magnetic augmentation function, and degaussing function into a single unit.

The tester features three‑phase simultaneous power‑on, independent current and voltage sampling, simultaneous measurement and display of three‑phase resistance values, and automatic calculation of the three‑phase unbalance rate. These capabilities significantly shorten the test period for transformer DC resistance and resolve the long‑standing issue of time‑consuming DC resistance measurement for each tap winding in power transformers.

 

Tech Data

Parameter Test Type Configuration / Current Range Corresponding Measurement Range
Output Current Three-phase 5A + 5A -
    1A + 1A -
    200mA + 200mA -
    20mA + 20mA -
  Single-phase 10A -
    5A -
    1A -
    200mA -
    20mA -
Measurement Range Three-phase 5A + 5A 2 mΩ ~ 1.2 Ω
    1A + 1A 10 mΩ ~ 6 Ω
    200mA + 200mA 100 mΩ ~ 30 Ω
    20mA + 20mA 10 Ω ~ 200 Ω
  Single-phase 10A 1 mΩ ~ 2 Ω
    5A 2 mΩ ~ 4 Ω
    1A 10 mΩ ~ 20 Ω
    200mA 100 mΩ ~ 100 Ω
    20mA 10 Ω ~ 20 kΩ
Accuracy Both (Three-phase / Single-phase) - ±(0.2% + 2 digits)
Minimum Resolution Both (Three-phase / Single-phase) - 0.1 μΩ

 

Notes

Before reversing the tap connections in the test of no-load voltage regulating transformers, be sure to reset the tester, wait till the end of the discharge process and the alarm stops. Before removing the wires, be sure to wait till the discharge process completes and the discharge alarm stops.

When the three channels are used, because the initial establishment of the magnetic circuit may take longer when testing the first set of data, the stabilization time can be shortened when the tap connections are reversed.

 

List of Complete Accessories

Name

Quantity

Transformer dc resistance tester host

1 unit

Dedicated test wires

1 set

Standard resistance

1 unit

Printing paper

2 rolls

Fuse

2 units

Grounding wire

1 unit

Power wire

1 unit

HZ-3310B Three Phase Transformer Winding DC Resistance Tester

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

Customer Visit

Case

Request for quote_

Hot Tags: hz-3310b 10a three phase transformer winding dc resistance tester, China, suppliers, manufacturers, price, for sale, 40A Winding Resistance Tester, winding resistance test of transformer, winding resistance tester 3 phase, 10a handheld dc resistance tester, 50A winding resistance test set, transformer winding dc resistance tester

Send Inquiry

(0/10)

clearall