+86-312-6775656
HZTTR80A TTR 3 Phase Transformer Ratiometer

HZTTR80A TTR 3 Phase Transformer Ratiometer

HZTTR80A TTR 3 Phase Transformer Ratiometer The HZTTR80A transformer ratio test set is a fully automatic testing device. It integrates functions for testing turn ratio, voltage ratio, vector relationship, winding connection group, polarity, tap position, and excitation current. This tester is a...
Product Details ofHZTTR80A TTR 3 Phase Transformer Ratiometer

 

HZTTR80A TTR 3 Phase Transformer Ratiometer

 

The HZTTR80A transformer ratio test set. It integrates functions for testing turn ratio, voltage ratio, vector relationship, winding connection group, polarity, tap position, and excitation current. This tester is a lightweight and portable instrument, with both the tester and its accessories housed in a multi-functional engineering plastic case that is resistant to cold, heat, moisture, and shocks, making it suitable for field tests.

 

Main Functional Features
▪ Capable of PT ratio and polarity testing.
▪ With a blind-testing function, it can accurately measure the turns ratio of a three-phase transformer even when its connection group type is unknown. It can also correctly determine the phase relationship between the primary and secondary sides and accurately calculate the group number.

▪ Capable of testing autotransformers, Z-type transformers, and phase-shifting transformers.
▪ Added tap mode settings to accommodate transformers with high voltage at high tap positions and low voltage at high tap positions.
▪ Added low-voltage side tap settings to accommodate transformers with taps on the low-voltage side.
▪ Graphical display settings for more intuitive readings.
▪ Simultaneous measurement of three-phase ratios during three-phase transformer testing for faster testing speed.

 

HZTTR80A01

HZTTR80A02

HZTTR80A03

Technical Parameters

Test Range Ratio: 0.9 to 10000
Current: 0 to 2000mA
Angle: 0 to 360°
Ratio Accuracy (80V Range) ±(0.1% + 2 digits) (Ratio: 0.9–500)
±(0.2% + 2 digits) (Ratio: 501–2000)
±(0.5% + 2 digits) (Ratio: 2001–10000)
Current Accuracy ±(1% of reading + 0.5mA)
Angle Accuracy ±0.2°
Output Voltage Selectable: 5V or 80V (AC)
Resolution Ratio: Minimum 0.0001
Current: 0.001mA
Angle: 0.01°
Test Voltage & Corresponding Current AC 5V @ 1A
AC 80V @ 80mA
Operating Power Supply Input Voltage: 100V to 240V AC
Frequency: 50/60Hz
Dimensions Main Unit: 360 × 290 × 170 mm
Cable Box: 360 × 290 × 170 mm

HZTTR80A

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

Customer Visit

Case

Request for quote_

Hot Tags: hzttr80a ttr 3 phase transformer ratiometer, China, suppliers, manufacturers, price, for sale, turns ratio test equipment, transformer turns ratio tester price, transformer turns ratio ttr tester, portable turns ratio tester, ttr transformation ratio tester, transformer turns ratio test set

Send Inquiry

(0/10)

clearall