+86-312-6775656
HZ-2000H Automatic Transformer Capacitance And Tan Delta Test Set

HZ-2000H Automatic Transformer Capacitance And Tan Delta Test Set

HZ-2000H automatic transformer capacitance and tan delta test set Usage Characteristics and Performance Automatic tan delta tester is integrated structure, built-in dielectric loss bridge, frequency conversion power supply, test transformer and standard capacitor. Frequency conversion anti-interference...
Product Details ofHZ-2000H Automatic Transformer Capacitance And Tan Delta Test Set

Huazheng Electric Manufacturing (Baoding) Co., Ltd. is one of the leading manufacturers and suppliers of hz-2000h automatic transformer capacitance and tan delta test set in China. Please feel free to buy high quality equipment for sale here from our factory. Good service and reasonable price are available.

 

HZ-2000H Automatic Transformer Capacitance And Tan Delta Test Set

CE Certification

Capacitance And Tan Delta Test Set

Usage Characteristics and Performance

The Automatic Transformer Tan Delta Test Set features an integrated structure, incorporating a built-in dielectric loss bridge, variable frequency power supply, test transformer, and standard capacitor. Utilizing frequency conversion anti-interference technology and Fourier transform digital filtering, it performs fully automatic and intelligent measurements. The measured data remain highly stable even in strong interference environments. Results are displayed on a large LCD screen and can be printed using a built-in micro printer.

The instrument also includes an insulation resistance measurement function. The connection mode for insulation resistance measurement is identical to that used for dielectric loss testing, allowing both parameters to be measured in a single setup. When this additional function is employed, it reduces the amount of equipment required on-site and minimizes test workload.

tan delta tester

Key Tech Data

ItemSpecification
AccuracyCₓ: ±(reading × 1% + 1 pF)
tgδ: ±(reading × 1% + 0.00040)
Anti-interference performanceFrequency conversion anti-interference; above accuracy maintained under 200% interference
Capacitance rangeInternal high voltage:
3 pF ~ 60000 pF / 10 kV
60 pF ~ 1.2 μF / 0.5 kV
External high voltage:
3 pF ~ 1.5 μF / 10 kV
60 pF ~ 30 μF / 0.5 kV
ResolutionCₓ: up to 0.001 pF, 4 significant digits
tgδ: 0.001%
tgδ rangeNo limit; automatic identification of capacitor, inductor and resistor
Test current range10 μA ~ 5 A
Internal high voltageVoltage range: 0.5 ~ 10 kV
Max output current: 200 mA
Voltage mode: continuous smooth adjustment
Voltage accuracy: ±(1.5% × reading + 10 V)
Voltage resolution: 1 V
Test frequency
49/51 Hz, 45/55 Hz auto dual-frequency conversion
Frequency accuracy: ±0.01 Hz
External high voltageForward connection: max test current 5 A / 40 ~ 70 Hz
Reverse connection: max test current 5 A / 40 ~ 70 Hz, up to 10 kV
CVT self-excitation (low voltage output)Output voltage: 3 ~ 50 V
Output current: 3 ~ 30 A
Measuring timeApprox. 30 s (depends on measurement method)


List of main tech parameters

Capacitance range

pF

Maximum output current mA

Shape size length x width x height

cm

Weight

kg

High voltage dielectric loss

CVT

Self-excitation measurement

Reverse connection low voltage side shield

Loop discharge prompt

Printing machine

3~60k

200/

10kV

34x26x27

22

Support

Simultaneous measurement of towable ground with high voltage connection without external equipment C1/C2

C1/C2

simultaneous measurement

yes

Temperature-sensitive

hz-2000h Tan Delta Test Set

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

Customer Visit

Case

Request for quote_

Hot Tags: HZ-2000H Automatic Transformer Capacitance And Tan Delta Test Set, China, suppliers, manufacturers, price, for sale, automatic capacitance and tan-delta test set, Tan delta diagnostic, Capacitance And Dissipation Factor Test Set, Tan Delta Meter, tan delta generator stator test, tandelta tester for transformer HZ-2000H, 10 kV Tan Delta testing of windings and bushing, HZ2000H, tandelta test, capacitance and tan delta test system, capacitance and dissipation factor measuring bridge, dielectric loss tangent delta tester, capacitance and dissipation factor tester, tan delta test equipment, Transformer Dielectric Loss Tangent Delta Tester, capacitance and tan delta tester