+86-312-6775656
Wxzk-IV Vacuum Interrupter Test Set Vacuum Circuit Breaker Tester Analyzer Switches Vacuity Tester

Wxzk-IV Vacuum Interrupter Test Set Vacuum Circuit Breaker Tester Analyzer Switches Vacuity Tester

Please notice that it's only allowed to work with well trained personnel and with the power systems familiar personnel.
Send Inquiry
Product Details of Wxzk-IV Vacuum Interrupter Test Set Vacuum Circuit Breaker Tester Analyzer Switches Vacuity Tester

Product Introduction

We are willing to work with a pragmatic and responsible attitude in order to dedicated to your high-quality and high-grade oil interfacial tension tester, sf6 gas dew point meter, dielectric strength test device. We conduct our business with integrity and demonstrate the highest ethical standards in our dealings with customers, suppliers and each other. With the development of society and economy, our company will keep a tenet of 'Focus on trust, quality the first', moreover, we expect to create a glorious future with every customer.

HZ-2009 High Voltage Switch Timing Test Circuit Breaker Analyzer

high-voltage circuit breaker analyzer is suitable for mechanical characteristic testing of SF6 switches, GIS composite electrical appliances, vacuum switches, and oil switches.

circuit breaker analyzer

High Voltage Circuit Breaker Analyzer Precautions

1. Please notice that it's only allowed to work with well trained personnel and with the power systems familiar personnel.

2. The connect action of the test lines should be done before supply power to the instrument.

3. When the instrument is turned on, do not touch the measurement circuit, control output circuit and the conductors connected to it. Before connecting the input or output terminals of the instrument, be sure to ground the instrument reliably.

4. Try to use the special test leads and accessories provided by this instrument.

5. In the case of connecting the DC output line, before turning on the power switch and control switch of the instrument, be sure to confirm that the switch is malfunctioning, so as not to cause any possible personal and equipment hazards.

6. Avoid using it in humid, flammable and explosive environments.

7. The power supply of the instrument is 220V AC, and 380V is prohibited.

HZ-2009 High Voltage Circuit Breaker Analyzer

High Voltage Circuit Breaker Analyzer

High Voltage Circuit Breaker Analyzer

High Voltage Circuit Breaker Analyzer

circuit breaker tester (3)

High Voltage Circuit Breaker Analyzer Technical Characteristics

Test channels

12 channels with 25V, the current is 50mA

Transducer

One analog transducer.

TIME

Recording time length

0~20.0s

Time accuracy

±0.l%reading ± 2 LSB

Resolution

0.1ms

Motion

Range

0~1000mm

Accuracy

±1% reading ±1LSB

Resolution

0.1mm

Velocity

Ranges

0.01~20.00m/s

Accuracy

±1%reading ±1LSB

Resolution

0.01m/s

DC POWER

Ranges

5~260V

Max current

20A

Accuracy

±1%reading ±1LSB

Load change

≤1%

TRIGGER

Voltage

5~260V

Current

0.1-20A

Transducer

The transducer states changes

Channels

Channels states changed

DIMENSIONS

415mm×320mm×168mm

WEIGHT

8kg

OPERATION TEMPERATURE

-10℃~50℃

HUMIDITY

≤80% RH

POWER SUPPLY

Voltage

AC 220V±10%

FREQUENCE

50Hz±10%

SAFETY

Insulation resistance

>2MΩ

Leakage current

<3.5mA

Immunity

AC 1500V 50Hz, 1min.

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

image012

image014

Request for quote_

We are a leading manufacturer of producing Wxzk-IV Vacuum Interrupter Test Set Vacuum Circuit Breaker Tester Analyzer Switches Vacuity Tester and providing related solutions. With integrated business of design, R&D, production, sales and service, we are committed to bringing the best benefits for customers. Our company is committed to developing products that meet customer needs, whether it is customized production or quantitative production. Since the establishment of our company, we have achieved fruitful results and formed a relatively mature management system.

Hot Tags: HZ-2009 High Voltage Switch Circuit Breaker Analyzer, China, suppliers, manufacturers, price, for sale, circuit breaker analyzer testing equipment, circuit breaker analyzer tester, circuit breaker analyzer hs code 90309090, High Voltage Switching Test System, hz-2009, hz2009, Circuit breaker vibration analyzer, circuit breaker analayser, high voltage circuit breaker analysis system, CB dynamic mechanical analyzer, transformer oil test machine, 40A Winding Resistance Tester, oil dielectric strength tester, transformer load loss measurement, transformer oltc tester, three phase power quality analyzer

[[ProKeywords]]

SPEC DATA

Send Inquiry

Send a Message