Transformer Oil Power Factor Test Set / Tan Delta Analyzer

Transformer Oil Power Factor Test Set / Tan Delta Analyzer

HZJD-2Z Automatic Insulating Oil Tangent Delta Tester is used for measuring dielectric loss dissipation factor and DC resistivity of insulating oil and other insulating liquids.
Send Inquiry
Product Details of Transformer Oil Power Factor Test Set / Tan Delta Analyzer

Product Introduction

While great achievements have been achieved in the domestic market, we also expect our TDR Cable Fault Locator, lab equipment astm d86 distillation apparatus, transformer onload tapchanger tester to enter the international market so that more people can understand and appreciate its superior performance. We maintain a good reputation and image, and strive to build an efficient cooperative team. To provide an inexhaustible and strong driving force for the sustainable development of the industry is one of our continuous progress goals.

HZJD-2Z Insulating Oil Dielectric Loss and Resistivity Tester

Brief Introduction

HZJD-2Z Insulating Oil Dielectric Loss and Resistivity Tester is usually used to measure the dielectric loss factor and DC resistivity of insulating oil and other insulating liquids. This instrument is characterized by an integrated structure, integrating the main components such as test unit, temperature controller, temperature sensor, standard capacitor, high resistance meter and DC high voltage source.

Features

The excellent quality of our Insulating Oil Dielectric Loss and Resistivity Tester makes us win the trust of customers. The instrument adopts full digital technology and intelligent automatic measurement, equipped with a large color screen (800 * 480) LCD display, which can display the test data in real time, making the operation simple and convenient. Its test results of each step can be automatically stored and printed out, so that operators without professional training will be able to use this insulating oil dielectric loss and resistivity tester skillfully.

Tech Data

Measuring range

Electric capacity

5pF~200pF

Relative Permittivity

1.000~30.000

Dielectric loss factor

0.00001~100

DC Resistivity

2.5MΩm~20TΩm

Measuring accuracy

Electric capacity

± (1% of measured value+0.5pF)

Relative Permittivity

±1% of measured value

Dielectric dissipation factor

± (1% of measured value+0.0001)

DC Resistivity

±10% of measured value

Resolution

Electric capacity

0.01pF

Relative Permittivity

0.001

Dielectric dissipation factor

0.00001

Measured temperature range

0~120℃

Temperature measurement error

±0.5℃

Test Voltage AC(RMS)

500~2000V Continuously adjustable, frequency 50Hz

Test Voltage DC

300~500V Continuously adjustable

Power consumption

100W

External dimensions

500×360×420

Total weight

22Kg

Use Condition

Ambient

Temperature:0℃~40℃

Relative

Humidity(RH):<75%

HZJD-2Z Insulating Oil Dielectric Loss and Resistivity Tester

HZJD-2Z Automatic Insulating Oil Dielectric Loss And Resistivity Tester

oil tan delta tester

Insulating Oil Dielectric Loss and Resistivity Tester

Insulating Oil Dielectric Loss and Resistivity Tester

Insulating Oil Dielectric Loss and Resistivity TesterInsulating Oil Dielectric Loss and Resistivity Tester

HZJD-2Z Insulating Oil Dielectric Loss and Resistivity Tester

Huazheng

image014

image016

Request for quote_

We have set a new development concept and service standard for the Transformer Oil Power Factor Test Set / Tan Delta Analyzer industry. We provide opportunities for our employees to shape their career competitiveness and achieve continuous self-achievement. We do not pursue egalitarianism, but pursue fairness, and guarantee to provide equal opportunities for every employee to show their strength.

Hot Tags: HZJD-2Z Insulating Oil Dielectric Loss and Resistivity Tester, China, suppliers, manufacturers, price, for sale, oil dielectric loss measuring instrument, oil dielectric loss and volume resistivity tester, Transformer oil dielectric loss testing equipment, Insulation Oil Dielectric Loss Angle Tester, oil dielectric loss factor measurement equipment, Oil Dissipation factor test, HZJD-2Z, electric insulation oil dielectric loss test machine, electric insulating oil dielectric loss analyzer, hzjd2z, insulation oil dielectric loss and electrical resistivity tester, AC Withstand Voltage Test vehicle, electric discharge rod, battery conductance test equipment, closed cup flashpoint tester, ac test transformer 50kv, du nouy ring tensiometer price

[[ProKeywords]]

SPEC DATA

Send Inquiry

Send a Message