Transformer High Voltage Switch Tap Changer Oil Purifier Fyz-20 (1200 LPH)
Product Introduction
We have a mature process and modern management model, committed to the development of Transformer Oil BDV Tester, transformer load loss measurement, dissolved gas analysis equipment, and manufacture products that meet the needs of target customers. In the years of development, our company has received sincere support from friends from all walks of life at home and abroad. I would like to extend my heartfelt gratitude to all walks of life, and sincerely welcome friends from all walks of life and people with lofty ideals to conduct extensive friendly cooperation and achieve advantages.Complement, win-win sharing, and create a better future. We support our buyers with ideal high quality products and high level service. We honor our core principal of Honesty in business, priority in company and will do our greatest to provide our customers with high-quality goods and fantastic provider. Without the dedication of our employees, the success of our company is impossible.
HZJF-9041D Four Channels Partial Discharge Detector

Overview
The HZJF-9041D four-channel partial discharge detector is a new type of digital partial discharge detection device developed by our company. While retaining all the advantages of the HZJF-9041 model, this product further reduces its size and optimizes its performance. It replaces the traditional oscilloscope and physical knob operation with a 10.1-inch touchscreen, making it more convenient to use.
This instrument features a fully touchscreen operation design, which not only enhances operational durability but also includes the following functions: one‑click automatic calibration, adjustable high‑voltage test divider ratio, and support for uploading test data via serial communication. The device offers high sensitivity, a wide range of applications, a broad dynamic range of the amplification system, multiple frequency band combinations (nine types in total), and strong anti‑interference capability. It is a practical partial discharge detection instrument widely used by power departments, manufacturing enterprises, and research institutions.
Main Technical Indicators
1. The equivalent capacitance ranges from 6pF to 250 μ F
2. Number of channels: Four channels
3. Measurement range: 0.1pc-10000nc
4. Detection sensitivity and allowable current (see Table 1)
NO. | Tuning Capacitance Range | Sensitivity (PC) (Unbalanced Circuit) | Effective Value Of Allowable Current | |
Unbalanced Circuit | Balance Circuit | |||
1 | 0~25~100pF | 0.02 | 30mA | 0.25A |
2 | 25~100~400pF | 0.04 | 50mA | 0.5A |
3 | 100~400~1500pF | 0.06 | 120mA | 1A |
4 | 400~1500~6000pF | 0.1 | 0.25A | 2A |
5 | 1500~6000~25000pF | 0.2 | 0.5A | 4A |
6 | 0.006~0.025~0.1μF | 0.3 | 1A | 8A |
7 | 0.025~0.1~0.4μF | 0.5 | 2A | 15A |
8 | 0.1~0.4~1.5μF | 1 | 4A | 30A |
9 | 0.4~1.5~6.0μF | 1.5 | 8A | 60A |
10 | 1.5~6.0~25μF | 2.5 | 15A | 120A |
11 | 6.0~25~60μF | 5 | 25A | 200A |
12 | 25~60~250μF | 10 | 50A | 300A |
7R | Resistance | 0.5 | 2A | 15A |
Table 1. Detection sensitivity and allowable current value of input unit
5. Elliptic scan time base
(1) Frequency 50/60, 100, 150, 200, 400Hz
(2) Rotation: 30 ° as the first gear, and can rotate 120 °
(3) Working method: ellipse sine wave straight line
6. Display unit
10.1 inch capacitive touch screen is used.
7. Amplifier
(1) 3dB low frequency fl:10, 20, 40KHz optional
(2) 3dB high frequency fh:80, 200, 300kHz optional
(3) Gain adjustment, rough adjustment 6, inter gear gain difference 20 ± 1dB, fine adjustment range >20db
(4) Asymmetry of positive and negative pulse response < 1dB
8. Time window
(1) Window width: adjustable, 5 ° ~ 170 ° at 50Hz
(2) Window position: each window can rotate 0 ° ~ 170 °
(3) Two time windows can be opened separately or simultaneously.
9. Peak pulse display
The touch screen displays 1 decimal place (10pc or more), 2 decimal places (less than 10pc), error: ± 3% (in full scale)
10. Test voltage display
(1) Range 150kV
(2) Input impedance: >1m Ω
(3) Display: touch screen display, display 1 decimal place
(4) Error: ± 1%
11. Test frequency display
Error: less than ± 1%
12. Zero standard system
Zero sign is consistent with all ellipse scanning frequencies
13. Structure
(1) Dimensions: 370mm (width), 460mm (depth), 215mm (height)
(2) Weight: about 12.5kg



We always provide high quality Transformer High Voltage Switch Tap Changer Oil Purifier Fyz-20 (1200 LPH) and services with the concept of integrity and sincere cooperation with every customer. We strictly control quality and price, and strive to deliver low-cost and high-quality products to customers. Welcome new and old customers to call and buy. Our company has advanced production equipment, professional technical personnel and high-quality management team.
Hot Tags: HZJF-9041D Four Channels Partial Discharge Detector, China, suppliers, manufacturers, price, for sale, 4 Channel Partial Discharge Tester, Multi-Channel Partial Discharge Detector, partial discharge detection equipment, Partial Discharge Measurement Device HZJF-9041D, partial discharge detection in high-voltage equipment, partial disharge detector, electrical partial discharge detector, Winding Resistance Measuring Kit, partial discharge test meter, transformer capacity test equipment, single phase transformer turns ratio test set, high voltage multifunction phasing stick, Closed Cup Flash Point Tester
[[ProKeywords]]SPEC DATA