+86-312-6775656
Transformer Dielectric Loss Tester/ Tan Delta Tester

Transformer Dielectric Loss Tester/ Tan Delta Tester

Accuracy: Cx: ±(reading×1%+1pF)
tgδ: ±(reading×1%+0.00040)
Anti-interference index: Frequency conversion anti-interference, the above accuracy can still be achieved under 200% interference
Send Inquiry
Product Details of Transformer Dielectric Loss Tester/ Tan Delta Tester

Product Introduction

Our company has a large amount of stock for all kinds of single phase relay test, transformer capacity noload & load test, hipot test transformer, striving to be the second warehouse of all users, providing timely and thoughtful services for all units. Through the marketing network all over the world, we can work closely with customers, communicate in time and make quick responses to meet the diverse needs of customers. Our company's technical team continues to actively introduce international technologies, always maintain product innovation and technological change, and constantly create new development opportunities for partners, and also provide customers with more convenient and efficient solutions. Our enterprise is based on integrity, harmony, innovation and development.

Product Introduction

The Transformer Dielectric Loss Tangent Delta Tester is an instrument specially designed for testing the capacity of standard distribution power transformers under low voltage and small current. Its main components include an LCD display, fuse box, grounding post, terminal block, etc. The Transformer Dielectric Loss Tangent Delta Tester is small in size and light in weight, with an integrated design that makes it easy to carry and operate in the field.

HZ-2000H Tangent Delta Tester

Features

HZ-2000H Transformer Dielectric Loss Tangent Delta Tester is sold well in the world market and worth recommendation for its excellent quality and reasonable price. Our tester can accurately measure the capacity of various distribution transformers with passive measurement, which is convenient and accurate. In addition, it comes with its own internal power supply and automatically generates three-phase high-power test power, which can measure no-load current, no-load loss, short-circuit voltage and short-circuit loss of various types of transformers.


Technical Index

Accuracy

Cx: ±(reading×1%+1pF)

tgδ

±(reading×1%+0.00040)

Anti-interference index

Frequency conversion anti-interference, the above accuracy can still be achieved under 200% interference

Electric capacity range

Internal high voltage:3pF~60000pF/10kV 60pF~1μF/0.5kV

External high voltage

3pF~1.5μF/10kV 60pF~30μF/0.5kV

Resolution

Up to 0.001pF, 4 significant digits

Range of tgδ

Unlimited, resolution 0.001%, automatic identification of three types of test samples: capacitance, inductance and resistance.

Test current range

10μA~5A

Internal high voltage

Setting voltage range 0.5~10kV

Maximum output current

200mA

Buck-boost mode

Voltage can be set at will. For example, 5123V.

Test frequency

40-70Hz single frequency can be set at will. For example, 48.7Hz.

50±0.1Hz to 50±10Hz automatic double frequency conversion can be set at will.
60±0.1Hz to 60±10Hz automatic double frequency conversion can be set at will.

Frequency accuracy

±0.01Hz

High voltage applied externally

The maximum test current is 5A during positive connection, power frequency or frequency conversion 40-70Hz. Maximum test current when reverse wiring is 10kV/5A, power frequency or frequency conversion 40-70Hz

CVT self-excited low voltage output

Output voltage 3~50V, output current 3~30A

Measuring time

About 40s, related to the measuring method

Input power

180V~270VAC, 50Hz±1%, power supply from mains or generator

Computer interface

Standard RS232 interface, U disk socket (automatic U disk storage data)

HZ-2000H

Transformer Tangent Delta Tester

Transformer Tangent Delta Tester

Transformer Tangent Delta Tester

HZ-2000H

Transformer Tangent Delta Tester

Measurement Method and Principle

According to whether the tested product is grounded or not, there are two kinds of measurement methods, namely, the forward connection measurement method and the reverse connection measurement method. The principles of the two measurement methods are shown in figure 1:

Tangent Delta Tester

At the 10kV side of the high-voltage power supply, the high-voltage power supply is divided into two channels, and the first channel feeds the standard capacitor CN inside the machine. The dielectric loss of this capacitor is very small, which can be considered as zero, i.e. pure capacitive current. This current ICN can be used as the capacitive current reference. On the Cx test side, the test current Icx is collected into the machine through the sampling resistance R. The Icx can be decomposed into horizontal and vertical components, as shown in figure 2. tgδ value can be obtained by calculating the ratio of the horizontal and vertical components.

In FIG. 1 (a), Cx is the ungrounded sample, and the sample current Icx enters the sampling resistance R from the sample end to obtain the full current value. In FIG. 1 (b), Cx is the grounding sample, the Cx end of the machine is directly grounded, and the current Icx obtains the full current value from the high-voltage end of the sample to the sampling resistance of the machine.

Tangent Delta Tester

hz-2000h

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

image052

image054

Request for quote_

We will continue to strengthen our production and service efficiency, expand our sales area, increase our product range and improve the quality of our Transformer Dielectric Loss Tester/ Tan Delta Tester in order to better meet our customers' requirements! We sincerely hope to provide you with high-quality products and services with our professional technology, responsible and rigorous attitude. 'Respect and develop the diverse talents of employees, help everyone realize their dreams' is one of our core values.

Hot Tags: HZ-2000H Transformer Dielectric Loss Tangent Delta Tester, China, suppliers, manufacturers, price, for sale, transformer tangent delta test, anti-interference dielectric loss tester, tangent delta test set, dielectric loss tangent test, tangente delta meter, transformer dielectric loss instrument, 10KV Insulation Power Factor Tester, HZ-2000H, Anti interference dielectric loss tester, tg delta test, tangen delta tester, 12 kv tan delta tester, tangent delta tester for motor, transformer onload tapchanger tester, Contact Resistance Measurement, cable fault pinpointer, lightening impulse test of transformer, Insulating Oil Gas Content Tester, Circuit Breaker Analysis kit

[[ProKeywords]]

SPEC DATA

Send Inquiry

Send a Message