Tester with AC DC Withstand Voltage Insulation Resistance Test Function
Product Introduction
We are determined to become the most trusted supplier of partial discharge test system, Cleveland Open Cup Flash Point Apparatus, secondary current injection test kit for users, insisting on technological innovation as the driving force, market demand as the guidance, continuous innovation, and improving the economic and social benefits of the enterprise. We should absorb talents with modern enterprise management strategies and management practices to join our team, in this way, our team building can keep pace with the pace of people-oriented and technology-leading corporate culture. The company adheres to the corporate mission of "revitalizing national industry" and always pursues the spirit of development and innovation.
HZG 50kV Dry Type AC DC Hipot Tester/ Dielectric Withstand Voltage Test Equipment
This series of test transformers utilizes advanced manufacturing equipment and incorporates new technologies, including epoxy vacuum casting for coil winding and a CD-type iron core. These innovations significantly reduce weight and volume while improving insulation strength and moisture resistance. In addition, leakage flux is effectively reduced, greatly enhancing the transformer's ability to withstand short-circuit current impacts during testing.

Technical Target
1. Impedance voltage | 4.5%-8% |
2. Idle load loss consumption | 0.2%-0.35% |
3. Allowable continuous operation time | 2 hours |
4. Interrupted operation time | continuous |



Major Technical Parameters
Model | Capacity | Input voltage | Output voltage | Output current | Output DC high voltage | Max. External dimension | Weight |
HZG-1.5/50 | 1.5 | 200 (400) | 50 | 30 | 70 | 250x180x370 | 13 |
HZG-3/50 | 3 | 60 | 330x270x600 | 30 | |||
HZG-5/50 | 5 | 100 | 400x330x700 | 48 | |||
HZG-6/50 | 6 | 120 | 300x310x680 | 46 | |||
HZG-10/50 | 10 | 200 | 430x370x750 | 73 | |||
HZG-20/50 | 20 | 400 | 470x370x750 | 85 | |||
HZG-30/50 | 30 | 600 | 500x380x780 | 120 | |||
HZG-5/100 | 5 | 100 | 50 | 140 | 430x370x1050 | 67 | |
HZG-10/100 | 10 | 100 | 470x370x1050 | 80 | |||
HZG-20/100 | 20 | 200 | 510x410x880 | 120 | |||
HZG-30/100 | 30 | 300 | 580x380x880 | 160 | |||
HZG-50/100 | 50 | 500 | 650x460x1010 | 230 |




It is the responsibility of every one of our staff to ensure the quality of our Tester with AC DC Withstand Voltage Insulation Resistance Test Function and the post-sale service of our products. We are constantly pushing the envelope to improve productivity and operational efficiency in response to market needs and customer concerns. We now have a lot of customers in Russia, European countries, the USA, the Middle East countries and Africa countries.
Hot Tags: HZG 50kV 5kVA Dry Type AC DC Hipot Tester, China, suppliers, manufacturers, price, for sale, AC DC Hipot Test Set, 50 kv hipot tester, AC DC Hipot Test Set, AC DC Hipot Test Equipment, ac hipot 250kv 300kv, HIPOT 50KV 50mA, HZG AC Hipot Test Set, 5kva 100kv dry type ac hipot test set, dry type high voltage tester, DC and AC High Potential test sets, acdc hipot test kits, high voltage dry type testing transformer, 50KV AC 70KV DC 3KVA Hipot Tester, hi pot tester hzg, 300kv 30kva ac dc hipot tester, dielectric strength puncture tester, cloud and pour point apparatus, Total Acid Number Tester, partial discharge free high voltage testing transformer, dc system ground fault detection, portable sf6 gas leakage detector, oil particle counter hydac
[[ProKeywords]]SPEC DATA