+86-312-6775656
Tdr /Arc High Voltage Underground Power Cable Fault Location System Equipment Tester Detector Price

Tdr /Arc High Voltage Underground Power Cable Fault Location System Equipment Tester Detector Price

Low resistance fault: if the insulation damage of the cable, can directly use the testing method of low voltage pulse of one class phase or phase to earth fault, called the leakage of low resistance fault
Send Inquiry
Product Details of Tdr /Arc High Voltage Underground Power Cable Fault Location System Equipment Tester Detector Price

Product Introduction

That has a sound business credit history, outstanding after-sales service and modern producing facilities, we have earned an superb popularity amid our buyers across the planet for megohmmeter 20kv, six phase protection relay test set, vlf high voltage generator. Our company adheres to technological innovation, and constantly pays attention to, tracks and grasps new technologies. The long-term and close cooperation between enterprises helps to reduce risks and transaction costs.

HZ-501A Underground Power Cable Fault Locator Price

Power Cable Fault Locator

Cable Fault Classification

Cable faults are primarily categorized based on their resistance characteristics and can be classified as low-resistance faults or high-resistance faults. High-resistance faults are further divided into leakage faults and flashover faults.

Low-Resistance Faults

A low-resistance fault occurs when the insulation of a cable is damaged, creating a conductive path between phase conductors or between a phase and ground. Such faults can be directly detected using the low-voltage pulse reflection method. These faults are generally characterized by a resistance value of less than a few hundred ohms. When the fault resistance drops to zero, it is specifically referred to as a short-circuit fault, which is a special case of low-resistance faults.

High-Resistance Leakage Faults

A high-resistance leakage fault occurs when the cable insulation medium is damaged and forms a fixed resistive channel, but the fault resistance is too high to be detected by the low-voltage pulse reflection method. Typically, the resistance value in such cases is several hundred ohms or higher. During on-site DC leakage voltage testing, the leakage current increases continuously as the applied DC voltage rises, eventually exceeding the standard allowable value for the cable. It is important to note that high-resistance leakage faults and low-resistance faults are described relative to each other, and there is no definitive boundary separating the two categories.

High-Resistance Flashover Faults

A high-resistance flashover fault occurs when the cable insulation is damaged but has not yet formed a fixed resistive channel. Within the pre-test voltage range, when the applied voltage reaches a certain threshold, the leakage current suddenly increases dramatically, far exceeding the cable's standard allowable value. This type of fault is characterized by its intermittent nature-the insulation breaks down under high voltage but may recover at lower voltages, making it distinct from leakage faults where a continuous conductive path exists.


Discrimination method of fault characteristics of power cable

(1) Judged by MΩmeter, multi meter.

(2) Judged by cable pre-testing result

(3) Judged by HZ-501A power cable pre-locator

Under normal circumstances, low resistance, open circuit fault can be directly judged by the Ohm meter or HZ-501A Power cable flashover instrument impulse testing wave.

Power cable fault testing program.

By applying the HZ-501A flashover instrument to locate the cable fault following procedures are generally required:

(1) Analyze the cable fault characteristics and learn about the cable rated voltage and the insulation materials.

(2) Using the HZ-501A Power cable Flashover instrument's impulse method to detect the cable length, and also to calibrate the radio wave speed in the fault cable.

(3) By selecting the suitable testing method, applying the HZ-501A Power cable flashover instrument to pre-locate the cable fault.

(4) To pin point the power cable fault precisely, include the underground cable route, depth and the fault point locating.

(5) Applying the tolerances analysis method to the cable fault testing results(measuring tolerances,transferring speed tolerances, judgments tolerances,instrument tolerances).

HZ-501A Cable Fault Detector

The Main Specification Index of System

1) Single-chip microprocessor platform with touch-screen operation

2) System functions: Fault distance measurement,Fault locating,transmission speed test,fault resistance,Power cable route tracing,buried depth detection etc

3) Detecting method: Low voltage impulse,Flash over method,Audio frequency method,Acoustic magnetic synchronous method,Valley value method,Peak method,Electromagnetic induction etc.

4) Display control: Flashover instrument: 8 inches industrial grade LCD, Battery inside, can work for 6 hours continually; others are Pointer table display

5) Detection range: testing distance: 30km, detection depth: 2-5m

6) Measurement accuracy: Pre-testing tolerances: ±10m (absolute value) or 1% (relative value), Precisely detecting tolerances: ±0.2m (Locating,route,depth)

7) Sampling frequencies: 80MHz,40MHz,20MHz,10MHz

8) Sampling method: automatic continuous sampling, no any discharging wave form can be left out absolutely.

9) Low voltage impulse: 0.05/0.1/0.2/0.5/1/2/8uS, seven

10) Output power: Route power: 100W,Impact power: 0~400W

11) Impact high voltage: 0~35kV

12) Short circuit current: 0~320mA

13) Burn through power: 0~1225J


Common problem and Solution

1. No response after start:

Check the AC 220V power supply;

Check whether the fuse is good

2. The voltage boot is not normal

Check the ground wire, high voltage ground wire is good and whether the adjust voltage knob is loosened;

3. High voltage can't be started.

Check if "Adjust Voltage" knob at zero;

4. Stop button is no response

Press the stop button for 2 to 7 seconds, or when pressing the stop button, to pull the start lever.

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

image006

image008

Request for quote_

Extraordinary design and perfect craft creation make our Tdr /Arc High Voltage Underground Power Cable Fault Location System Equipment Tester Detector Price always in the leading position. Our company strives for the development by the unceasing innovation and creates the good achievement by the legal management. The unit's technical strength, product quality, and thoughtful after-sales service are deeply trusted by users in terms of reputation.

Hot Tags: HZ-501A Underground Electrical Power Cable Fault Locator, China, suppliers, manufacturers, price, for sale, underground cable fault locating equipment, cable fault locator machine, electrical cable fault detector, cable fault location system, tdr cable fault locator all in one, cable fault located, 32kv power test fault locator system, copper cable fault locator, Cable fault locating equipment, tdr cable tester, hz-501a, LV Power Cable Fault Locator, cable fault locator factory, under ground cable fault locator, cable fault locator kit, insulation resistant tester, electrical rescue hook, interfacial tension test for transformer oil, Surge Counter Tester, astm d473 crude oil sediment, contact resistance tester 200a

[[ProKeywords]]

SPEC DATA

Send Inquiry

Send a Message