
Sweep Frequency Response Analysis Method Sfra Test for Transformer
Product Introduction
The company specializes in the operation and service of high-quality electrical power transformer test bench, sf6 gas leakage detector, vlf hipot test set, and is good at dealing with some difficult problems in practice. Over the years of operation, we have established an extensive sales network with a number of professional engineering and technical personnel to provide you with strong technical support and guarantee. Our company has practical experience in training management team and creating excellent performance.
Product Introduction
The Transformer Winding Deformation Tester is based on the measurement of the characteristic parameters of the transformer's internal windings and adopts advanced analysis methods to make accurate judgments on the internal faults of the transformer. The Sweep Frequency Response Analysis Transformer Winding Deformation Tester is suitable for power transformers with voltage levels of 6kV and above and other special-purpose transformers.
Features
Our Transformer Winding Deformation Tester uses the sweep frequency method to measure the transformer winding characteristics, with fast measurement speed and very high frequency accuracy. And it uses digital frequency synthesis, which has higher frequency stability. In addition, it is highly intelligent and easy to operate. Its detection data is automatically analyzed, and electronic documents can be automatically generated for storage and printing.
Main Tech Data
Measuring speed | 1 minute to 2 minutes for single-phase winding |
Output voltage | Automatic adjustment during Vpp-25V test |
Output impedance | 50Ω |
Input impedance | 1MΩ (built-in 50Ω matching resistance in response channel) |
Sweep frequency range | 10Hz-2MHz |
Frequency accuracy | 0.001% |
Sweep mode | Linear or logarithmic, sweep interval and number of points can be set arbitrarily |
Curve display | Amplitude-frequency curve |
Wide measuring dynamic range | -120dB~20dB |
Power supply voltage | AC220V±10% |
HZ-600A SFRA Transformer Winding Deformation Tester







Packing List
No. | Name | Qty |
1 | Collector Module | 1 |
2 | Excitation Cable(Red) | 2 |
Response Cable(Yellow) | 1 | |
Ground Cable & Pincers | 2 | |
Excitation Pincers(Red) | 1 | |
Response Pincers(Yellow) | 1 | |
3 | USB Cable | 1 |
4 | Y Type Tee | 2 |
5 | Power Cable | 1 |
6 | PE Cable | 1 |



We are committed to improving product quality, developing and updating products in order to continuously provide customers with quality Sweep Frequency Response Analysis Method Sfra Test for Transformer and comprehensive services. We continue to expand market space, strengthen scientific research and development efforts, optimize product structure, strict quality management, maintain sustained and stable development, and provide users with better products and services. Our company takes the customer as the center, pursues the product and the service and satisfies the customer's actual demand and the potential demand.
Hot Tags: HZ-600A Sweep Frequency Response Analysis Transformer Winding Deformation Tester, China, suppliers, manufacturers, price, for sale, sweep frequency response analysis test, power transformers winding deformation detection, sweep frequency response analysis (sfra) measurement, Sweep Frequency Response Analyser HZ-600A, hz600a, Winding Deformation Diagnosing Sfra Tester, elactric safety hook, Primary Current Injection Test Equipment, digital tan delta tester, transformer oil filtration machine price, non partial discharge testing transformer, dc motor winding resistance test
[[ProKeywords]]SPEC DATA
Send Inquiry
