Sm66 Hv Indoor 10~24kv Sf6 Insulated Ring Main Unit
Smart calibration: The sensor probe automatically calibrates to zero point to ensure the accuracy for each measurement
Product Introduction
We are committed to providing customers with all-round and precise services to meet their various needs. We provide a variety of products based on many years of experience in the production of series resonance test equipment, 20kv insulation resistance tester, 3 phase relay test set. We combine advanced information technology and management methods from abroad with the specific realities of domestic companies. While opening up a broader market and serving customers, all of our staff will continue to be down-to-earth, brave in innovation, and strive to provide customers with better products and considerate services. If the quality of our products causes you economic loss, personal injury, etc., our company will definitely be responsible for the compensation and service follow-up, and will never delay.
HZSF-702 SF6 Gas Dew Point Moisture Meter

Feature
Portable design | light, portable, convenient to use. |
Smart calibration | The sensor probe automatically calibrates to zero point to ensure the accuracy for each measurement; |
Rapid measurement | When start work,it takes a short time on measurement,and get the humidity value. |
Low gas consume | It just consume 2L(101.2kPa)in a test. |
Self-locking joint | The self-locking joint is imported from Germany, safe, reliable, leak-proof. |
Data memory | High-capacity design, save up to 200set test data. |
Legible display | Dew point, Micro moisture (ppm), ambient temperature, ambient humidity, time, date, battery, etc, can be read from the LCD. |
RS232 port | Can be connected with serial printer, carry on data printing. |
Accurate measurement | Increases the temperature compensation function to ensure the accuracy of measurement results under various temperature conditions. |
Open calibration | This unit comes with a calibration function that allows you to calibrate the data without connecting to a computer. |

Specification
Dew point | Ranges | -80℃~+ 20℃ |
Accuracy | ±1℃(-60℃~+ 20℃)or ±2℃(-80℃~-60℃) | |
Response time | 63% takes 5s, 90% takes 45s / 63% takes 10s, 90% takes 240s | |
Ambient temperature | -40℃~+80℃ | |
ambient humidity | 0~100% RH | |
LCD display | 4.3 inch touch screen | |
Power | AC 220V | |
Built-in rechargeable battery | ||
Battery | Charge 20 hours, operating 10 hours | |
Operation
1. Connect To SF6 Electrical Equipment
Connect the screw thread port to the switch joint, screw up it, then close the needle valve on the other head of the tube.
Connect the quick coupling of the test tube to the inlet of the meter.
Connect the vent tube to the outlet.
At last, screw up the switch joint to the SF6 electrical equipment.
2. Initialization
Power on the meter, it will take 5 seconds to initialize.
3. Check The Battery
The meter takes precedence for use alternating current.
when use DC power, view the battery on top right corner. when the battery indicates the electricity less than 20%, please recharge the equipment and then begin to use.
4. Start
Open all needle valves of stream tube, use flow valve adjust flow to about 0.5L/M, then begin to measure the dew point of SF6.
It takes 5-10 minutes for the first measurement, followed test will only need take 3-5 minutes for each device.
5. Save Data
After test,save the data and print it.
6. Test Other Equipment
When complete one set of equipment, close the needle valve of the stream tube and turn off flow valve. Take the adapter off from SF6 electrical equipment. If any equipment needs to be tested repeat steps above.
7. Test Complete
After all tests, Please turn off the equipment.



At present, we have established extensive business relationships with many domestic and foreign Sm66 Hv Indoor 10~24kv Sf6 Insulated Ring Main Unit enterprises. We are equipped with factory-level intelligent control system to provide customers with a set of high reliability, cost-effective solutions. We will take casting the best brand as the goal to provide you with the best product. We make the quality culture permeate every field and become a conscious behavior of the company's employees.
Hot Tags: HZSF-702 SF6 Gas Dew Point Moisture Meter, China, suppliers, manufacturers, price, for sale, sf6 gas moisture content measurement, sf6 dew point tester, sf6 gas dew point meter, SF6 Gas Dew Point Test Equipment, HZSF-702 dew point test of sf6 gas, Handheld SF6 Dew Point Analyzer, chilled mirror dew point meter, Chilled Mirror Dew Point Meter Instrument, ct pt test set, electrical rescue hook, brake fluid boiling point tester, insulation resistance tester huazheng, dc system earth fault tester, Battery Internal Resistance And Conductance Tester
[[ProKeywords]]SPEC DATA