+86-312-6775656
Sm66 Hv Indoor 10~24kv Sf6 Insulated Ring Main Unit

Sm66 Hv Indoor 10~24kv Sf6 Insulated Ring Main Unit

Portable design: Light、portable、convenient to use.
Smart calibration: The sensor probe automatically calibrates to zero point to ensure the accuracy for each measurement
Send Inquiry
Product Details of Sm66 Hv Indoor 10~24kv Sf6 Insulated Ring Main Unit

Product Introduction

We are committed to providing customers with all-round and precise services to meet their various needs. We provide a variety of products based on many years of experience in the production of series resonance test equipment, 20kv insulation resistance tester, 3 phase relay test set. We combine advanced information technology and management methods from abroad with the specific realities of domestic companies. While opening up a broader market and serving customers, all of our staff will continue to be down-to-earth, brave in innovation, and strive to provide customers with better products and considerate services. If the quality of our products causes you economic loss, personal injury, etc., our company will definitely be responsible for the compensation and service follow-up, and will never delay.

HZSF-702 SF6 Gas Dew Point Moisture Meter

SF6 Gas Dew Point Meter

Feature

Portable design

light, portable, convenient to use.

Smart calibration

The sensor probe automatically calibrates to zero point to ensure the accuracy for each measurement;

Rapid measurement

When start work,it takes a short time on measurement,and get the humidity value.

Low gas consume

It just consume 2L(101.2kPa)in a test.

Self-locking joint

The self-locking joint is imported from Germany, safe, reliable, leak-proof.

Data memory

High-capacity design, save up to 200set test data.

Legible display

Dew point, Micro moisture (ppm), ambient temperature, ambient humidity, time, date, battery, etc, can be read from the LCD.

RS232 port

Can be connected with serial printer, carry on data printing.

Accurate measurement

Increases the temperature compensation function to ensure the accuracy of measurement results under various temperature conditions.

Open calibration

This unit comes with a calibration function that allows you to calibrate the data without connecting to a computer.

SF6 Gas Dew Point Meter

Specification

Dew point

Ranges

-80℃~+ 20℃

Accuracy

±1℃(-60℃~+ 20℃)or ±2℃(-80℃~-60℃)

Response time

63% takes 5s, 90% takes 45s / 63% takes 10s, 90% takes 240s

Ambient temperature

-40℃~+80℃

ambient humidity

0~100% RH

LCD display

4.3 inch touch screen

Power

AC 220V

Built-in rechargeable battery

Battery

Charge 20 hours, operating 10 hours

Operation

1. Connect To SF6 Electrical Equipment

Connect the screw thread port to the switch joint, screw up it, then close the needle valve on the other head of the tube.

Connect the quick coupling of the test tube to the inlet of the meter.

Connect the vent tube to the outlet.

At last, screw up the switch joint to the SF6 electrical equipment.

2. Initialization

Power on the meter, it will take 5 seconds to initialize.

3. Check The Battery

The meter takes precedence for use alternating current.

when use DC power, view the battery on top right corner. when the battery indicates the electricity less than 20%, please recharge the equipment and then begin to use.

4. Start

Open all needle valves of stream tube, use flow valve adjust flow to about 0.5L/M, then begin to measure the dew point of SF6.

It takes 5-10 minutes for the first measurement, followed test will only need take 3-5 minutes for each device.

5. Save Data

After test,save the data and print it.

6. Test Other Equipment

When complete one set of equipment, close the needle valve of the stream tube and turn off flow valve. Take the adapter off from SF6 electrical equipment. If any equipment needs to be tested repeat steps above.

7. Test Complete

After all tests, Please turn off the equipment.

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

image006

image008

Request for quote_

At present, we have established extensive business relationships with many domestic and foreign Sm66 Hv Indoor 10~24kv Sf6 Insulated Ring Main Unit enterprises. We are equipped with factory-level intelligent control system to provide customers with a set of high reliability, cost-effective solutions. We will take casting the best brand as the goal to provide you with the best product. We make the quality culture permeate every field and become a conscious behavior of the company's employees.

Hot Tags: HZSF-702 SF6 Gas Dew Point Moisture Meter, China, suppliers, manufacturers, price, for sale, sf6 gas moisture content measurement, sf6 dew point tester, sf6 gas dew point meter, SF6 Gas Dew Point Test Equipment, HZSF-702 dew point test of sf6 gas, Handheld SF6 Dew Point Analyzer, chilled mirror dew point meter, Chilled Mirror Dew Point Meter Instrument, ct pt test set, electrical rescue hook, brake fluid boiling point tester, insulation resistance tester huazheng, dc system earth fault tester, Battery Internal Resistance And Conductance Tester

[[ProKeywords]]

SPEC DATA

Send Inquiry

Send a Message