+86-312-6775656
Power Frequency Withstand Voltage Test Set/ Partial Discharge Test System

Power Frequency Withstand Voltage Test Set/ Partial Discharge Test System

HZIR-1000 SF6 infrared quantitative detector adopts high-speed embedded MCU, Chinese touch man-machine interface, and the operation is simple and clear.
Send Inquiry
Product Details of Power Frequency Withstand Voltage Test Set/ Partial Discharge Test System

Product Introduction

Over the years, we have carefully polished and innovated our products for the sake of making Cleveland Open Cup Flash Point Apparatus, transformer dc resistance tester, primary current injection test set manual. Warmly welcome to join us, let's innovation collectively, to flying dream. We carry out perfect testing methods, quick and thoughtful pre-sales and after-sales services. We keep enriching the connotation of enterprise culture of "technology first, quality first, pursuit of excellence, integrity world", actively participate in the market competition.

HZIR-1000 High Accuracy Portable Infrared Quantitative SF6 Gas Leak Detector

HZIR-1000 Infrared Quantitative SF6 Gas Leak Detector

Overview

HZIR-1000 SF6 infrared quantitative detector adopts high-speed embedded MCU, Chinese touch man-machine interface, and the operation is simple and clear. The sensor is imported from Germany based on the technical principle of the dual-wave non-dispersive infrared spectrometer (NDIR). The complete hardware and software design of the SF6 gas leak infrared leak detector provides reliable and high-precision performance and maintenance-free features. It also provides functions such as data storage and USB data export. The equipment is stable, reliable and high-precision performance.

Main Technical index

Minimum detection value

0.1ppm

Detection range

0~1000ppm

Response time

<3 seconds

Recovery time

<5 seconds

Reference error

≤±1%[0~1000] ppm ≤±5%[1000~5000] ppm

Repeat error

≤2%

Display mode

3.5-inch color touch screen display

The detection length of the probe gun

straight rod type 130mm

Continuous working time

≥8 hours

Instrument power

Four-cell lithium battery

Charging voltage

8.4 volts, photoelectric time 5 hours (continuous charging does not exceed 12 hours)

Matters needing attention

(1) This equipment performs operational function verification every two years.

(2) In order to ensure the personal safety of the operator and the safety of the equipment, the terms in the instructions for use must be observed.

(3) This equipment is a special tool for detecting SF6 gas. It is forbidden to detect other gases and use illegally.

(4) This device cannot be used in a working area where explosive gas mixtures have not been proven.

(5) The instructions of the operation manual are kept with the equipment at all times and kept by the operator.

(6) The operator must be familiar with the technical instructions and instructions in the manual.

(7) The operator must be familiar with the safety measures, safe operation and cleaning and maintenance of this equipment,

(8) Engineers and technicians with certain professional knowledge are required to operate this equipment.

(9) The operator must read this manual thoroughly and understand the importance of SF6 gas measurement safety.

(10) The personnel managing this equipment must be serious, reliable, responsible and possess certain professional knowledge.

(11) People who are drunk, whose thinking is disturbed, or who have not received professional training are also prohibited from operating this equipment.

(12) You must be responsible for the consequences if you change or disassemble the equipment without authorization, or damage it in violation of the operating regulations.

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

image005

image007

Request for quote_

The demand for our Power Frequency Withstand Voltage Test Set/ Partial Discharge Test System is growing, thus we are constantly innovating and upgrading our technology to meet customer requirements. With advantage of industry management, the company has always been committed to supporting customers to become the market leader in their respective industries. Our company's image, credibility, product technology quality assurance and production capacity have been well received by the majority of users.

Hot Tags: HZIR-1000 Infrared Quantitative SF6 Gas Leak Detector, China, suppliers, manufacturers, price, for sale, portable sf6 gas leak detector, sf6 gas leak detection, sf6 gas leakage tester, portable sf6 gas leak detector, sf6 circuit breaker leak testing, SF6 Leak Detectors and Gas Analysis Equipment HZIR-1000, SF6 Gas Leak Detector manual, sf6 gas leak detector, Karl Fischer Moisture Analyzer, 3000a high current generator, capacitance and tan delta test set, Insulation Resistance Tester, paraffin wax content tester

[[ProKeywords]]

SPEC DATA

Send Inquiry

Send a Message