
Pillow Bag Automatic Industrial Bandage Packing Machine
Product Introduction
Our company has a long history of producing tan delta test equipment, Transformer Routine Test, Single Phase Relay Tester, with a deep accumulation of technology and experience. Our company's quality policy is to meet the needs of customers with stable quality management and continuous improvement. We hope to reshape the value chain of sharing and value-added, and promote the common development of the industry and even the society.
HZSF-821 SF6 Gas Purity Test Set

Technical Characteristics
Portable design | The instrument is lighter, easier to carry and use. |
Fast measurement | There is no need to wait after the instrument is turned on, and the measurement is performed immediately to obtain the purity value quickly. |
Fast gas saving | The gas consumption is only about 0.5L (101.2kPa) during measurement. |
Self-locking joint | The self-locking joint imported from Germany is safe, reliable and free of air leakage. |
Data storage | Large-capacity design can store up to 100 sets of test data. |
Clear display | The LCD screen directly displays the purity value, time and date, battery power and other content. |
RS232 interface | It can be connected to a serial printer for data printing. |
Built-in power supply | Built-in large-capacity rechargeable lithium battery, which can work continuously for 10 hours at a time. |

Technical Parameters
Purity | Measuring range | 0%~100% |
Measuring accuracy | ±0.5% | |
Measuring time | <2 minutes | |
Ambient temperature | -40℃~+60℃ | |
Environment humidity | 0~100% RH | |
Power supply | AC 220V | |
Built-in rechargeable battery | ||
Battery performance | Charging time is more than 20 hours and can be used for 10 hours | |
Weight | 3 kg | |
Dimension | 250×100×300mm | |
Operating temperature | -30℃~+50℃ | |
Matters Needing Attention
l The instrument should be placed in a safe place to prevent it from being broken and avoid severe vibration;
l Do not measure corrosive gases;
l When adjusting the gas flow, the flow valve should be opened slowly so that the flow indication is about 0.2 liters/ minute;
l Before using the instrument, it should be charged in time. When charging, you only need to connect the power cord to the 220V socket. There is no need to turn on the power switch. The instrument will automatically charge. The charging time generally takes more than 20 hours.



Our eternal pursuits are the attitude of 'regard the market, regard the custom, regard the science' and the theory of 'quality the basic, belief the very first and management the advanced' for Pillow Bag Automatic Industrial Bandage Packing Machine. We actively respond to the market, adjust the export strategy keenly, and improve our response to the international market. So that you can utilize the resource from the expanding info in international trade, we welcome shoppers from everywhere on-line and offline.
Hot Tags: HZSF-821 SF6 Gas Purity Test Set, China, suppliers, manufacturers, price, for sale, sf6 gas purity analyzer, SF6 Gas Purity Tester, sf6 gas purity test equipment, sf6 purity meter, Routine SF6 gas testing, SF6 Gas Purity Analyser HZSF-821, SF6 Circuit breaker purity test, SF6 Gas Purity Test Equipment, Ground Lead Underline Conduction Tester, battery impedance tester, lead acid battery discharger, LUBRICITY WEAR TESTER, Dc load bank, 3 channels transformer winding resistance meter
[[ProKeywords]]SPEC DATA
Send Inquiry
