+86-312-6775656
Partial Discharge Meter,

Partial Discharge Meter,

HZJF-9041D partial discharge detector is a new type of digital partial discharge detector developed by our company. It retains the advantages of HZJF-9041 partial discharge detector
Send Inquiry
Product Details of Partial Discharge Meter,

Product Introduction

In our view, quality and service are not only economic indicators, but also humanistic indicators. We are committed to highlighting tan delta test, Transformer Routine Test, sf6 dew point analyzer quality, value and service characteristics, so that the good relationship established between us and customers can be sustained development and the market is full of competition. Our premise of cultivating consumer loyalty is to strengthen the construction of marketing ethics and create and deliver valuable products or services for consumers. Selling our products causes no risks and brings high returns to your company instead. As a rapidly developing production enterprise, our production capacity is increasing year by year. We insist on people-oriented and pursue the happiness of material life and spiritual and cultural double harvest of all employees.

HZJF-9041D Four Channels Partial Discharge Detector

partial discharge detector

Overview

The HZJF-9041D four-channel partial discharge detector is a new type of digital partial discharge detection device developed by our company. While retaining all the advantages of the HZJF-9041 model, this product further reduces its size and optimizes its performance. It replaces the traditional oscilloscope and physical knob operation with a 10.1-inch touchscreen, making it more convenient to use.

This instrument features a fully touchscreen operation design, which not only enhances operational durability but also includes the following functions: one‑click automatic calibration, adjustable high‑voltage test divider ratio, and support for uploading test data via serial communication. The device offers high sensitivity, a wide range of applications, a broad dynamic range of the amplification system, multiple frequency band combinations (nine types in total), and strong anti‑interference capability. It is a practical partial discharge detection instrument widely used by power departments, manufacturing enterprises, and research institutions.


Main Technical Indicators

1. The equivalent capacitance ranges from 6pF to 250 μ F

2. Number of channels: Four channels

3. Measurement range: 0.1pc-10000nc

4. Detection sensitivity and allowable current (see Table 1)

NO.

Tuning Capacitance Range

Sensitivity (PC) (Unbalanced Circuit)

Effective Value Of Allowable Current

Unbalanced Circuit

Balance Circuit

1

0~25~100pF

0.02

30mA

0.25A

2

25~100~400pF

0.04

50mA

0.5A

3

100~400~1500pF

0.06

120mA

1A

4

400~1500~6000pF

0.1

0.25A

2A

5

1500~6000~25000pF

0.2

0.5A

4A

6

0.006~0.025~0.1μF

0.3

1A

8A

7

0.025~0.1~0.4μF

0.5

2A

15A

8

0.1~0.4~1.5μF

1

4A

30A

9

0.4~1.5~6.0μF

1.5

8A

60A

10

1.5~6.0~25μF

2.5

15A

120A

11

6.0~25~60μF

5

25A

200A

12

25~60~250μF

10

50A

300A

7R

Resistance

0.5

2A

15A

Table 1. Detection sensitivity and allowable current value of input unit

5. Elliptic scan time base

(1) Frequency 50/60, 100, 150, 200, 400Hz

(2) Rotation: 30 ° as the first gear, and can rotate 120 °

(3) Working method: ellipse sine wave straight line

6. Display unit

10.1 inch capacitive touch screen is used.

7. Amplifier

(1) 3dB low frequency fl:10, 20, 40KHz optional

(2) 3dB high frequency fh:80, 200, 300kHz optional

(3) Gain adjustment, rough adjustment 6, inter gear gain difference 20 ± 1dB, fine adjustment range >20db

(4) Asymmetry of positive and negative pulse response < 1dB

8. Time window

(1) Window width: adjustable, 5 ° ~ 170 ° at 50Hz

(2) Window position: each window can rotate 0 ° ~ 170 °

(3) Two time windows can be opened separately or simultaneously.

9. Peak pulse display

The touch screen displays 1 decimal place (10pc or more), 2 decimal places (less than 10pc), error: ± 3% (in full scale)

10. Test voltage display

(1) Range 150kV

(2) Input impedance: >1m Ω

(3) Display: touch screen display, display 1 decimal place

(4) Error: ± 1%

11. Test frequency display

Error: less than ± 1%

12. Zero standard system

Zero sign is consistent with all ellipse scanning frequencies

13. Structure

(1) Dimensions: 370mm (width), 460mm (depth), 215mm (height)

(2) Weight: about 12.5kg

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

image003

image005

Request for quote_

Our company will rely on equipment innovation and technological progress to continuously improve the technical quality of employees to ensure that enterprises provide customers with better Partial Discharge Meter,. We will continue to work hard, with good products and more powerful measures to continue to serve our customers and to achieve win-win situation. We analyze the needs of individual users and understand changes and growth trends in user needs, knowing our customers better.

Hot Tags: HZJF-9041D Four Channels Partial Discharge Detector, China, suppliers, manufacturers, price, for sale, 4 Channel Partial Discharge Tester, Multi-Channel Partial Discharge Detector, partial discharge detection equipment, Partial Discharge Measurement Device HZJF-9041D, partial discharge detection in high-voltage equipment, partial disharge detector, electrical partial discharge detector, machine oil purifier, kf titrator, battery discharge capacity tester, underground power cable locator, 3ka primary injection test system, cable fault locator surge generator

[[ProKeywords]]

SPEC DATA

Send Inquiry

Send a Message