Hz-600A Sweep Frequency Response Analysis Method Sfra Test in Transformer
Product Introduction
We strive to reflect the concept of combining modern design concepts, mature technical levels and professional and considerate services in our vlf cable tester, lab equipment astm d86 distillation apparatus, Total Acid Number Tester. In the development of our company, we try our best to provide competitive treatment for our employees and make greater tax contribution for the local area. Our continuous optimization of design solutions and modern management concepts make us a trusted partner for our customers. We actively carry out cooperation with enterprises and internationally, promote and apply the latest research results, and develop simultaneously with the world's advanced technologies.
Product Introduction
The Transformer Winding Deformation Tester is based on the measurement of the characteristic parameters of the transformer's internal windings and adopts advanced analysis methods to make accurate judgments on the internal faults of the transformer. The Sweep Frequency Response Analysis Transformer Winding Deformation Tester is suitable for power transformers with voltage levels of 6kV and above and other special-purpose transformers.
Features
Our Transformer Winding Deformation Tester uses the sweep frequency method to measure the transformer winding characteristics, with fast measurement speed and very high frequency accuracy. And it uses digital frequency synthesis, which has higher frequency stability. In addition, it is highly intelligent and easy to operate. Its detection data is automatically analyzed, and electronic documents can be automatically generated for storage and printing.
Main Tech Data
Measuring speed | 1 minute to 2 minutes for single-phase winding |
Output voltage | Automatic adjustment during Vpp-25V test |
Output impedance | 50Ω |
Input impedance | 1MΩ (built-in 50Ω matching resistance in response channel) |
Sweep frequency range | 10Hz-2MHz |
Frequency accuracy | 0.001% |
Sweep mode | Linear or logarithmic, sweep interval and number of points can be set arbitrarily |
Curve display | Amplitude-frequency curve |
Wide measuring dynamic range | -120dB~20dB |
Power supply voltage | AC220V±10% |
HZ-600A SFRA Transformer Winding Deformation Tester







Packing List
No. | Name | Qty |
1 | Collector Module | 1 |
2 | Excitation Cable(Red) | 2 |
Response Cable(Yellow) | 1 | |
Ground Cable & Pincers | 2 | |
Excitation Pincers(Red) | 1 | |
Response Pincers(Yellow) | 1 | |
3 | USB Cable | 1 |
4 | Y Type Tee | 2 |
5 | Power Cable | 1 |
6 | PE Cable | 1 |



We guarantee our Hz-600A Sweep Frequency Response Analysis Method Sfra Test in Transformer of high quality with strong technical strength, scientific production management method and raw material of good quality. Facing the new demand of market changes and the new round of challenges in the industry, we will do our best with the passion of entrepreneurs to create greater value for our customers. Adhering to the concept of openness, tolerance, and work together, our employees are diverse and diligent, and each brings different skills, experience and unique perspectives.
Hot Tags: HZ-600A Sweep Frequency Response Analysis Transformer Winding Deformation Tester, China, suppliers, manufacturers, price, for sale, sweep frequency response analysis test, power transformers winding deformation detection, sweep frequency response analysis (sfra) measurement, Sweep Frequency Response Analyser HZ-600A, hz600a, Winding Deformation Diagnosing Sfra Tester, dc high voltage test for cables, astm d473 crude oil sediment, SF6 Gas Analyzer, calorific value measuring instrument, astm d86 distillation machine, winding resistance test set
[[ProKeywords]]SPEC DATA